Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

Fabric OS Message Reference 455
53-1000600-01
Chapter
73
TRCE System Messages
TRCE-1001
Message <timestamp>, [TRCE-1001], <sequence-number>,, WARNING, <system-name>, Trace dump
available< optional slot indicating on which slot the dump occurs >! (reason:
<Text explanation of what triggered the dump. (PANIC DUMP, WATCHDOG EXPIRED,
MANUAL, TRIGGER)>)
Probable Cause Indicates that trace dump files have been generated on the switch or the indicated slot. The reason
field indicates the cause for generating the dump as one of the following:
PANICDUMP generated by panic dump
WATCHDOG EXPIRED generated by hardware watchdog expiration
MANUAL generated by the tracedump -n command
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity WARNING
TRCE-1002
Message <timestamp>, [TRCE-1002], <sequence-number>,, INFO, <system-name>, Trace dump<
optional slot indicating on which slot the dump occurs > automatically transferred
to FTP address ' <FTP target designated by user> '.
Probable Cause Indicates that a trace dump has occurred on the switch or the indicated slot and is successfully
transferred from the switch automatically.
Recommended
Action
No action is required.
Severity INFO