Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

518 Fabric OS Message Reference
53-1000600-01
SULB-1004
86
SULB-1004
Message AUDIT, <timestamp>, [SULB-1004], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwarecommit has completed.
Probable Cause Indicates that the FirmwareCommit command is executed.
Recommended
Action
No action is required. Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1009
Message AUDIT, <timestamp>, [SULB-1009], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload command failed. status: 0x<status code>,
error: 0x<error code>.
Probable Cause Indicates that the firmwareDownload command failed. The additional status code and error code
provide debugging information.
Table lists firmwareDownload status messages and status codes. Some of them will not show up
in this RASLOG message. They are listed for the sake of completeness.
TABLE 9 Status Messages and Status Codes
Status Message Status Code
firmwareDownload sanity check failed. 0x30
"Sanity check failed because system is non-redundant." 0x31
“Sanity check failed because firmwareDownload is already in progress.” 0x32
"Sanity check failed because FABRIC OS is disabled on Active CP." 0x33
"Sanity check failed because HAMD is disabled on Active CP." 0x34
“Sanity check failed because firmwareDownload is already in progress.” 0x35
"Sanity check failed because FABRIC OS is disabled on Standby CP." 0x36
"Sanity check failed because HAMD is disabled on Standby CP." 0x37
firmwareDownload failed on Standby CP.” 0x40
firmwareDownload failed on Standby CP.” 0x41
firmwareDownload failed on Standby CP.” 0x42
firmwareCommit failed on Standby CP.” 0x43
firmwareDownload failed. 0x44
firmwareDownload failed due to IPC error. 0x50
"Unable to check the firmware version on Standby CP due to IPC error." 0x51
firmwareDownload failed due to IPC error. 0x52
firmwareDownload failed due to IPC error. 0x53
"Standby CP failed to reboot due to IPC error." 0x54