Brocade Error Message Reference Guide v6.0.0 (53-1000600-01, April 2008)

30 Fabric OS Message Reference
53-1000600-01
AG-1019
2
Recommended
Action
Run switchShow to display the status of all ports in the system. Run portCfgShow to display a list of
ports currently configured as N_Port(s). Ensure that the host is connected to an F_port.
Severity ERROR
AG-1019
Message <timestamp>, [AG-1019], <sequence-number>,, WARNING, <system-name>, Unable to
failover N_Port <port>. No other N Port in port group:<pgid> is online.
Probable Cause Failover across port groups is not supported.
Recommended
Action
Please check whether or not an alternate N_Port is configured in this port group.
Severity WARNING
AG-1020
Message <timestamp>, [AG-1020], <sequence-number>,, INFO, <system-name>, F_Ports to
N_Ports route/mapping has been changed.
Probable Cause Indicates that F_Ports to N_Ports mapping has been changed because the switch has come online
or some new N_Port/F_Port has come online.
Recommended
Action
Run the ag --mapshow command to display the updated F_Port to N_Port mapping.
Severity INFO
AG-1021
Message <timestamp>, [AG-1021], <sequence-number>,, WARNING, <system-name>, Unable to do
Preferred-Failover of F_Port <port>. Failover across different fabric is not
supported.
Probable Cause Failover across N_Ports connected to different fabrics is not supported.
Recommended
Action
Please change the preferred N_Port settings for this F_Port using ag --prefset.
Choose the preferred N_Port such that it is in the same fabric as the primary N_Port of this F_Port.
Use ag --show to check the fabric connectivity of N_Ports.
Severity WARNING
AG-1022
Message <timestamp>, [AG-1022], <sequence-number>,, INFO, <system-name>, F_Port <fport>
is failed over to its preferred N_Port <nport>.