Chapter 43, Performance Data
1
Uncompressed
Tx/Rx MB/sec
FCIP SNMP .1.3.6.1.4.1.1588.4.1.1.6 (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX EE Monitors HTTP PortRX (variable from the
return html file)
TX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
RX EE Monitors HTTP PortTX (variable from the
return html file)
RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX HBA, CNA HCM API N/A TX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
RX HBA, CNA HCM API N/A RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX TE SNMP .1.3.6.1.2.1.31.1.1.1.6 TX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
RX TE SNMP .1.3.6.1.2.1.31.1.1.1.10 RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX% / RX% FC, GE,
HBA, CNA
N/A N/A TX% or RX% = ((TX or RX) /
((105000000 * port speed)*
(polling interval
2
))) * 100
If utilization is less than 1, the value
is 0.0.
TX% / RX% FCIP N/A N/A TX% or RX% = ((bytes transferred) /
(maximum bytes transmitted))*100
where maximum bytes transmitted =
tunnel speed * 134217728 (maximum
bytes transmitted 1 Gbps).
If utilization is less than 1, the value
is 0.0.
TX% / RX%
(Pre-Fabric OS
6.4.1 release)
TE N/A N/A TX% or RX% = ((TX or RX) /
((105000000 * 10)*
(polling interval
2
))) * 100
If utilization is less than 1, the value
is 0.0.
Compression
Ratio
FCIP N/A .1.3.6.1.4.1.1588.4.1.1.4 Compression Ratio = current value/ 1000
The compression ratio is the current
compression ratio value.
Receive EOF TE .1.3.6.1.2.1.16.1.1.1.5 Receive EOF = delta value
1
/
(1000 * 1000)
Other
3
Other counters = delta value
1
1. The difference of the value retrieved between two consecutive polling cycles.
2. The duration between two polling cycle in seconds.
3. Additional performance counters are detailed in Table 1.
TABLE 1 Performance statistic counters
Counter name Type Protocol Source OID value Formula