Brocade Network Advisor 12.1.X Documentation Updates (53-1003016-05, January 2014)
Table Of Contents
- Cover
- Contents
- About This Document
- Brocade Network Advisor SAN + IP User Manual
- In this chapter
- Chapter 4, Discovery
- Chapter 9, View Management
- Chapter 35, Image Repository for IP Products
- Chapter 39, Global Server Load Balancing
- Chapter 43, Performance Data
- Chapter 44, Flow Vision
- Chapter 50, Monitoring and Alerting Policy Suite
- Appendix A, Application menus
- Appendix E, Device Properties
- Brocade Network Advisor SAN User Manual
- Brocade Network Advisor IP User Manual
- Brocade Network Advisor Installation and Migration Guide
- Virtual Connect Enterprise Manager Server Guide
- CLI Templates
- Database tables and fields
- Views
- ADAPTER_PORT_CONFIG_INFO
- AG_CONNECTION_INFO
- BOOT_IMAGE_FILE_DETAILS_INFO
- CNA_ETH_PORT_CONFIG_INFO
- CNA_PORT_DETAILS_INFO
- CNA_PORT_INFO
- CORE_SWITCH_DETAILS_INFO
- CRYPTO_HOST_LUN_INFO
- CRYPTO_TARGET_ENGINE_INFO
- DASHBOARD_PREFERENCES_INFO
- DEPLOYMENT_INFO
- DEPLOYMENT_LOG
- DEVICE_CONNECTION_INFO
- EE_MONITOR_STATS_5MIN_INFO
- EE_MONITOR_STATS_30MIN_INFO
- EE_MONITOR_STATS_2HOUR_INFO
- EE_MONITOR_STATS_1DAY_INFO
- TE_PORT_STATS_5MIN_INFO
- TE_PORT_STATS_30MIN_INFO
- TE_PORT_STATS_2HOUR_INFO
- TE_PORT_STATS_1DAY_INFO
- SWITCH_INFO
- DEVICE_INFO
- N2F_PORT_MAP_INFO
- DEVICE_NODE_INFO
- DEVICE_PORT_INFO
- DEV_PORT_GIGE_PORT_LINK_INFO
- DEV_PORT_MAC_ADDR_MAP_INFO
- ISL_CONNECTION_INFO
- ISL_INFO
- ETHERNET_ISL_INFO
- EVENT_DETAILS_INFO
- EVENT_INFO
- FABRIC_INFO
- FCIP_TUNNEL_CIRCUIT_INFO
- FCIP_TUNNEL_INFO
- FCOE_DEVICE_INFO
- FRU_INFO
- GIGE_PORT_ECLOUD_LINK_INFO
- GIGE_PORT_INFO
- HBA_PORT_DETAILS_INFO
- HBA_TARGET_INFO
- HEALTH_STATUS_INFO
- HOST_DISCOVERY_REQUEST_INFO
- IFL_INFO
- ISL_INFO
- ISL_TRILL_INFO
- ISL_TRUNK_GROUP_MEMBER_INFO
- ISL_TRUNK_INFO
- L2_NEIGHBOR_INFO
- MAPS_EVENT_DETAILS_INFO
- MODULE_INFO
- NPORT_WWN_MAP_INFO
- PHANTOM_PORT_INFO
- PRODUCT_INFO
- PORT_BOTTLENECK_CONF_INFO
- PORT_BOTTLENECK_STAT_INFO
- PORT_GROUP_INFO
- ROLE_PRIVILEGE_INFO
- SCOM_EE_MONITOR_INFO
- SENSOR_INFO
- SMART_CARD_USAGE_INFO
- SWITCH_CONFIG_INFO
- SWITCH_DETAILS_INFO
- SWITCH_PORT_INFO
- SWITCH_SNMP_INFO
- TIME_SERIES_DATA_INFO
- TIME_SERIES_DATA_VIEW
- USER_ROLE_RESOURCE_INFO
- VIRTUAL_FCOE_PORT_INFO
- VIRTUAL_PORT_WWN_DETAILS_INFO
- VM_ADDRESS_INFO
- VM_CONNECTIVITY_INFO
- VM_DATASTORE_DETAILS_INFO
- VM_EE_MONITOR_INFO
- VM_HOST_INFO
- VM_LUN_INFO
- VM_STATISTICS_INFO
- VR_CONN_MODULE_INFO
- VR_CONN_MODULE_PORT_INFO
- VR_CONN_NPIV_INFO
- VMM_DISCOVERED_MAC_INFO
- VM_VIRTUAL_ETHERNET_ADAPTER_INFO
- ZONE_DB_INFO
- PHYSICAL_DEVICE_INFO
- SLOT_INFO
- MANAGED_ELEMENT_INFO
- SNMP_DATA_INFO
- SNMP_EXPR_DATA_INFO
- SNMP_DATA_VIEW
- VM_VNETWORK_INFO
- CEE_PORT_INFO
Brocade Network Advisor SAN User Manual 1405
53-1002948-01
Database tables and fields
H
CURRENT_SPEED Current speed of the remote port, as enforced by
TRL.
The default value is 0.
varchar 64
TRL_ENFORCED True if TRL(Target Rate limit) is enforced. varchar 16
BUS_NO Channel number in the PCI Bus. The default value is
0.
varchar 32
FCP_IM_STATE Indicates whether the Fibre Channel Protocol Input
Method (FCP-IM) is online or offline.
varchar 128
IO_LATENCY_MIN Minimum IO Latency value (< 79) in milliseconds and
is calculated when HBA port starts SCSI (FCP)
exchanges
varchar 32
IO_LATENCY_MAX IO Latency value in milliseconds and is calculated
when HBA port starts SCSI (FCP) exchanges
varchar 32
IO_LATENCY_AVERAGE Average IO Latency value in milliseconds and is
calculated when HBA port starts SCSI (FCP)
exchanges
varchar 32
DATA_RETRANSMISSION_S
UPPORT
Field to indicate whether the remote port supports
data retransmission.0 would mean unsupported and
nonzero value implies supported. The default value is
0.
smallint
REC_SUPPORT Field to indicate whether the remote port supports
the REC ELS command Channel number in the PCI
Bus.Zero would mean unsupported and nonzero
value implies supported. The default value is 0.
smallint
TASK_RENTRY_IDENT_SUP
PORT
The number of PRLI responses from the target to the
initiator and begins when HBA Port starts FCP
exchanges.Zero would mean unsupported and
nonzero value implies supported. The default value is
0.
int
CONFIRMED_COMPLETION
S_SUPPORT
The number of confirmed completions on the remote
port and begins when HBA Port starts FCP
exchanges.Zero would mean unsupported and
nonzero value implies supported. The default value is
0.
int
TABLE 219 HBA_REMOTE_PORT_LUN
Field Definition Format size
ID Auto generated primary key int
HBA_REMOTE_PORT_ID Primary key of owner row in Remote Port int
FCP_LUN The logical unit number of Fibre Channel Protocol
(FCP) device. The default value is 0.
varchar 16
CAPACITY The capacity of the logical unit. The default value is
0.
int
BLOCK_SIZE The block size of the logical unit, in bytes (for
example, 512 Bytes). The default value is 0.
int
TABLE 218 HBA_REMOTE_PORT (Continued)
Field Definition Format Size