HP Storage Essentials V5.1 User Guide First Edition (T4283-96026, August 2006)

Event Management462
7. Change the value assigned to the cimom.ClariionEventPollInterval property. The
value is in milliseconds. In the example below, the polling interval is set to 5 minutes.
cimom.ClariionEventPollInterval=300000
8. When you are done, click Save.
9. Restart the service for the management server for your changes to take effect.
While AppStorManager is restarting, users are not able to access the management server. The
AppStorManager service must be running for the management server to monitor elements.
Important: While the AppStorManager service is stopped, the following occurs:
Users are not be able to access the management server.
The management server is unable to monitor elements at this time.
Brocade Events
This section describes the following:
Brocade Switch Events” on page 462
Supported Brocade Events” on page 463
Brocade Switch Events
When a Brocade switch generates an event, it assigns a code to the event instead of an event
severity level. So, the software assigns an event severity level to the event according to the event's
code. This lets you filter Brocade switch events by severity level in Event Manager, as described in
the following table.
NOTE: Events regarding firmware downloads are removed from the following table since the
management server cannot be made aware of those events.
Table 73 Brocade Switch Events
*Code Event
Severity
Level
*Name Description
0Minor
EV_OBJ_CHANGED
A physical fabric object (switch
port or fabric) has changed
state.
1Major
EV_OBJ_DELETE
One or more physical fabric
objects (device port, switch, or
fabric) have disappeared.