HP Storage Essentials V5.00.01 installation guide (T4283-96011, January 2006)
Table Of Contents
- HP
- Storage Essentials 5.00.01 Installation Guide
- Contents
- Overview
- Installing the Management Server on Microsoft Windows
- Discovering Filers, Tape Libraries, Switches and Storage Systems
- Deploying CIM Extensions
- Installing the CIM Extension for IBM AIX
- Installing the CIM Extension for SGI ProPack for Linux
- Installing the CIM Extension for HP-UX
- Installing the CIM Extension for SUSE and Red Hat Linux
- Installing the CIM Extension for OpenVMS
- Installing the CIM Extension for HP Tru64 UNIX
- Installing the CIM Extension for SGI IRIX
- Installing the CIM Extension for Sun Solaris
- Installing the CIM Extension for Microsoft Windows
- Discovering Applications, Backup Servers and Hosts
- Managing Security
- Troubleshooting
Storage Essentials 5.00.01 Installation Guide 65
• SNMP connection - Enter the IP address of the proxy. The default user name is “public” (the
read-only community string). The password does not matter since the management server is
not doing any configurations through SNMP.
10.Verify the following on the proxy and the switches accessible from the proxy:
• The SNMP agent is enabled.
• The read-only community string is configured.
11.Run Discovery.
12.Run Get Details.
(Discovery from SE Only) Excluding McDATA and EMC Connectrix Switches
from Discovery
IMPORTANT: This step only applies to discovery from SE only.
Specific McDATA and Connectrix switches can be excluded from discovery by using system
properties.
To exclude one or more switches from discovery, you must modify the
cimom.mcdata.exclude
property. Set the property cimom.mcdata.exclude to a comma separated list of Worldwide
Names of the McDATA and Connectrix switches you want excluded, as shown in the following
example:
cimom.mcdata.exclude=1000080088A07024,1000080088A0D0B6
The management server excludes the switches with one of the following Worldwide Names:
1000080088A07024 and 1000080088A0D0B6
If the cimom.mcdata.exclude property is not modified, the management server discovers and
obtains details from all McDATA and Connectrix switches.
IMPORTANT: The IP addresses of excluded elements appear in the discovery lists (Tools >
Storage Essentials > Home > Discovery > Setup), topology (Tools > Storage Essentials >
Home > Discovery > Topology), or Get Details lists (Tools > Storage Essentials > Home >
Discovery > Details). The management server does not display additional information about
excluded elements in the user interface. The management server, however, does mention in the logs
(Tools > Storage Essentials > Home > Discovery > View Logs) that a provider instance has
been created for an excluded element. You can ignore this message that appears in the logs.
To modify the
cimom.mcdata.exclude property:
1. Select Options > Storage Essentials > Manage Product Health. Then, click
Advanced in the Disk Space tree.
2. Click Show Default Properties at the bottom of the page.