HP OpenView Storage Mirroring User Guide (360226-002, May 2004)

13 - 17
NSIPHDriver 9008 Error Could not write registry value for subnet
mask list for adapter
Reboot the server and contact technical
support if this event occurs again.
9009 Error Could not form full registry path to
adapter
Reboot the server and contact technical
support if this event occurs again.
Recognizer 12288 Error Nsi-recognizer was started improperly.
Nsi-recognizer must be started during
boot. Change Nsi-recognizer's Startup
value to Boot in the Devices applet of
Control Panel, then reboot the system.
In the Control Panel Devices applet,
change NSI-recognizer Startup value to
Boot. Reboot the server for the change to
take effect.
Resources 8192 Warning Kernel memory was exhausted.
Replication is stopped.
Contact technical support if this event
occurs again.
8192 Error Failed to create device list entry due to
insufficient resources.
Contact technical support if this event
occurs again.
8193 Error Failed to create Transfer Thread. The last
Word in the Data Window is the NT
status code.
Reboot the server and contact technical
support if this event occurs again.
8194 Error Failed to create filename work queue. The
last Word in the Data Window is the NT
status code.
Reboot the server and contact technical
support if this event occurs again.
8195 Error Failed to create file close queue. The last
Word in the Data Window is the NT
status code.
Reboot the server and contact technical
support if this event occurs again.
8196 Warning The maximum amount of memory for
replication queuing has been reached.
Replication is stopped and memory is
being freed.
Contact technical support if this event
occurs again.
8197 Error Failed to create file delete queue. The last
Word in the Data Window is the NT
status code.
Reboot the server and contact technical
support if this event occurs again.
8198 Error Failed to save the registry path. The last
Word in the Data Window is the NT
status code.
Reboot the server and contact technical
support if this event occurs again.
8199 Error Failed to create tracked file queue. The
last Word in the Data Window is the NT
status code.
Reboot the server and contact technical
support if this event occurs again.
8200 Warning Failed to allocate buffer for querying very
long filenames, i.e., names over 260
characters. Replication will continue for
standard length filenames. The last Word
in the Data Window is the NT status
code.
Reboot the server and contact technical
support if this event occurs again.
8201 Warning Reached stop replicating page limit.
Replication is stopped.
Configure the applications on the server
to use less memory or add more memory
so that the server does not get into a low
memory state.
8201 Warning Reached stop replicating page limit.
Replication is stopped.
Configure the applications on the server
to use less memory or add more memory
so that the server does not get into a low
memory state.
Category ID Severity Message Required Response