HP StorageWorks Storage Mirroring scripting guide (T2558-96074, February 2008)

9 - 8
2. If necessary, review the failover settings by using the monitor display command.
3. To stop failover monitoring, use the monitor stop command.
Command TARGET
Description Identifies a machine as the active target machine
Syntax
TARGET <target>
Options target—Name of the target, an IP address on the target, or a virtual IP address
Examples
target beta
Notes You must be logged into a machine using the login command before using the target
command.
Target names that contain non-alphanumeric characters must be enclosed in quotation marks.
Command MONITOR DISPLAY
Description Displays the monitoring and failover configuration settings for the specified monitor machine
Syntax
MONITOR DISPLAY <monitor>
Options monitor—Name of the source machine designated as the monitor
Examples
monitor display alpha
Notes If you do not specify a monitor, the current source designated as the monitor will be used. If you
have not identified a monitor, you will receive an error message stating that a monitor has not
been selected.
Monitor names that contain non-alphanumeric characters must be enclosed in quotation marks.
Command MONITOR STOP
Description Stops monitoring the source machine for a failure
Syntax
MONITOR STOP <monitor> [ON <target_machine>]
Options monitor—Name of the source machine designated as the monitor
target—Name of the target, an IP address on the target, or a virtual IP address
Examples
monitor stop alpha on beta