HP StorageWorks 2000 Modular Smart Array racking instructions (494159-001, July 2008)

HP StorageWorks
2000 Modular Smar t Array
racking instructions
© Copyright 2008 Hewlett-Packar d Development Company, L.P.
First ed
ition: May 2008
The information in this document is subject to change without notice.
Printed in China
www.hp.
com
494159-001
Audience assump
tions
This document is for the person who installs, administers, and
troubleshoots servers and storage systems. HP assumes that you are
qualied in the servicing and installation of computer equipment and are
trained in recognizing hazards in products and hazardous energy levels.
Rack planning and resources
The HP StorageWorks 2000 Modular S mart Array (MSA2000) supports
the HP 10000 series of racks. For information about setting up the rack,
including the appropriate warnings and cautions, see the documentation
that came with the rack. Updated rack information can be downloaded
from the HP website h
ttp://www.hp.com/products/racks.
NOTE:
Other racks might also be suitable, but have not been tested.
Site requirements
Detailed site requirements are provided at the end of this document
and in the user guide. Before installing, verify that the installation site
meets the
system requirements for:
space and
airow
tempera
ture
power an
dgrounding
Contents
Description Quantity
Rear rail brackets
2
Front rail brackets
2
Side br
ackets
2
Cage nuts 10
Hanger pins
6
8-32 x
3/16 Phillips at-head screws
4
6-32 x 1/4 Phillips pan-head screws
3
8-32 x 3/8 Phillips at-head screws
6
10-32 x
3/4 Phillips truss-head screws
8
10-32x5/8Phillipsat-head screws
2
Rack installati
on
HP recommends i
nstalling all enclosures at the bottom of the rack. To
optimize cabli
ng access, avoid interleaving the enclosure and server
products.
Step 1: Install cage nuts
Front
IMPORTANT:
The placemen
t of the middle cage nut i s different on the right
and left side on the front of the rack.
NOTE:
The markings shown are provided for illustration purposes only;
your device may be installed in a different location.
Rear
Step 2: Assemble rails
1. Slide the rear rails into the front rails.
2. Align the rst, third, and fth holes in the rear rail bracket with the
slots of the front bracket. Loosely install three 8-32 x 3/8 Phillips
at-head screws in each rail set. They will be tightened after rails
are installed.
3. Install two hanger pins into the front and one into the rear of each
rail set.
Step 3: Install rails on the rack
1. Use the hanger pins to hang the rails on the rack.
Front Align the middle screw hole with the middle cage nut.
Rear—Alignthetwoscrewholeswiththecagenuts.
2. Secure the front of ea ch rail to the rack with one 10-32 x 5/8
Phillips at-head screw (middle hole).
3. Secure the rear of each rail to the rack with two 10-32 x 3/4
Phillips truss-head screws.
4. Tighten the screws holding the front and rear rail brackets together.