HP StorageWorks 1000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual (AA969-90904, September 2004)

Troubleshooting and Diagnostics
191000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual
DESTINATION
2 #
SCSI element to which the second destination
refers. (This information is valid for the
EXCHANGE movement only.)
ODOMETER #
Move number in which the error occurred.
*
MICROMOVE 1
#
First jukebox micro-move for the original move
command issued prior to the failure.
*
MICROMOVE 2
#
Second jukebox micro-move for the original
move command issued prior to the failure.
*
MICROMOVE 3
#
Third jukebox micro-move for the original move
command issued prior to the failure.
*MICROMOVE 4
#
Fourth jukebox micro-move for the original move
command issued prior to the failure.
*
MICROMOVE 5
#
Fifth jukebox micro-move for the original move
command issued prior to the failure.
*
MICROMOVE 6
#
Sixth jukebox micro-move for the original move
command issued prior to the failure. (This is the
last to be logged.)
*MICROMOVE ER #
Micro-move error that occurred.
TOP or BOTTOM
PICKER
Displays either TOP or BOTTOM indicating
which side of the disk transport mechanism was
active at the time of the error.
NORTH or SOUTH
THUMB
Displays either NORTH or SOUTH indicating
which thumb on the transport mechanism was
active at the time of the error.
Table 3: Information logs (Continued)
Log name Description