HP StorageWorks 1000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual (AA969-90904, September 2004)

Troubleshooting and Diagnostics
24 1000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual
Recovery procedures for specific hardware errors
When a hardware failure occurs, a message displays on the control panel. If the failure occurs
during the power-on sequence, DEVICE FAILED displays. If the failure occurs when loading
a disk you may see LOAD ERROR or FULL. If a failure occurs while you are running a test,
TEST FAILED displays. When you press ENTER, the jukebox displays information about
the hardware failure from the error log.
The jukebox firmware can detect broken components such as a dead motor, but if failures are
due to marginal or random problems, the failing component may induce errors in other
components. For example, if the electronics produce an intermittent error or if friction
increases on a part, different components of the jukebox may appear to fail. Several error
codes may be displayed as a result of one problem.
Table 5 shows the hardware error codes possible and recovery procedures for specific
hardware errors.
Table 5: Hardware errors verification/recovery
Error Code (hex) Verification/Recovery Procedures
01
ROM checksum error
Errors 01 to 07 are only possible on power-up. Replace the
controller PCA.
02
Register error
See error 01.
03
Microprocessor error
See error 01.
04
Controlled area of RAM
checksum error
See error 01.
05
RAM test error
See error 01.
06
SCSI chip error
See error 01.
07
Jukebox controller chip
error
See error 01.
0F
ID configuration module
failure
Occurs if:
A configuration module for another model of jukeboxes is
installed
The configuration module was removed while power was on
the configuration module chip failed during periodic polling
Check the SLOTS display under INFO * / JUKEBOX * menu for
correct number of slots detected for the jukebox.