HP StorageWorks 1000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual (AA969-90904, September 2004)

Troubleshooting and Diagnostics
30 1000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual
5E
Powerfail clear path
1. Check that all paths are clear.
2. Test the vertical path sensor operation.
5F
Powerfail restore
cartridges
A cartridge was physically moved after powerfail and before
powerfail recovery.
Check that no cartridges have been moved.
60
Repeater controller
1. Check cables between the controller PCA and the SCSI
repeater PCA.
2. Check the external cables.
3. Change repeater PCA.
4. Change the controller PCA.
5. Change internal SCSI cable
61
External SCSI cables
1. Check for correct terminator (single-ended or differential) for
the type of SCSI interface chosen.
2. Change external SCSI cable.
3. Change SCSI repeater PCA.
4. Change the controller PCA.
62h
Test media
The test of media type in a mixed media unit failed.
For 1000ux/1900ux/2300ux models:
Verify that the media detect station is installed in the correct
position, below drive 3.
For 3800ux/7100ux models:
Verify that the media detect station is installed in the correct
position, below drive 10.
Table 5: Hardware errors verification/recovery (Continued)
Error Code (hex) Verification/Recovery Procedures