HP StorageWorks 1000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual (AA969-90904, September 2004)

Troubleshooting and Diagnostics
311000ux/1900ux/2300ux and 3800ux/7100ux Optical Jukebox Service Manual
Micro-move error codes
Table 6: Micro-move error codes
Micro-Move Error
Code (hex)
Description
01 Vertical over voltage exceeded limit set by firmware
02 Vertical over force exceeded limit set by firmware
03 Vertical servo error
04 Vertical time-out
05 Vertical open path
06 Vertical closed path
0A Plunge over voltage exceeded limit set by firmware
0B Plunge over force exceeded limit set by firmware
0C Plunge servo error
0D Plunge servo error
0E Plunge open path
0F Plunge closed path
10 Top picker expected to be active picker in plunge (run-time)
11 Bottom picker expected to be active picker in plunge (run-time)
12 Bottom thumb expected to be active in plunge home (powerup)
13 Top thumb expected to be active in plunge home (powerup)
14 Translate over voltage exceeded limits set by firmware
15 Translate over force exceeded limits set by firmware
16 Translate servo error
1E No load complete
1F Unexpected load complete
20 Unexpected cartridge in drive
21 No cartridge in drive
22 Drive put in accept failed
23 Drive get out accept failed
24 Drive eject failed
25 Drive insert failed
26 Drive eject retry
27 Drive insert retry
28 Clear drive path
29 Drive signal (not used)
2A Drive not connected
32 Magazine put in saturate failed
33 Magazine get out saturate failed
34 Magazine put in accept failed
35 Magazine get out accept failed