Brocade Fabric OS Command Reference Manual Supporting Fabric OS v7.0.0 (April 2011)

Fabric OS Command Reference 921
53-1001764-01
slotShow
22
DISABLED
The blade is powered on but disabled.
FAULTY
The blade is faulty because an error was detected.
UNKNOWN
The blade is inserted but its state cannot be determined.
NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS This command supports the following operands:
-p
In addition to the basic slot status view, displays the following information about
power consumption:
Total direct current (DC) power consumption for the chassis and individual
values for each blade (in Watts). Note that usage for other components is
included but not listed.
Total alternating current (AC) power consumption in Watts.
AC efficiency, as a percentage of total and BTU.
Power efficiency in Watts/port and Watts/Gb.
-m
In addition to the basic slot status view, displays the Brocade model name for
each blade.
EXAMPLES To display the status of all slots on a DCX 8510-8:
switch:user> slotshow
Slot Blade Type ID Status
---------------------------------
1 UNKNOWN VACANT
2 AP BLADE 43 ENABLED
3 UNKNOWN VACANT
4 SW BLADE 97 ENABLED
5 CORE BLADE 98 ENABLED
6 CP BLADE 50 ENABLED
7 CP BLADE 50 ENABLED
8 CORE BLADE 98 ENABLED
9 AP BLADE 75 ENABLED
10 SW BLADE 97 ENABLED
11 SW BLADE 77 ENABLED
12 SW BLADE 96 ENABLED
To display the Brocade model name for each blade on a Brocade DCX 8510-8:
switch:user> slotshow -m
Slot Blade Type ID Model Name Status
--------------------------------------------------
1 UNKNOWN VACANT
2 AP BLADE 43 FS8-18 ENABLED
3 UNKNOWN VACANT
4 SW BLADE 97 FC16-32 ENABLED
5 CORE BLADE 98 CR16-8 ENABLED
6 CP BLADE 50 CP8 ENABLED