Brocade Network Advisor SMI Agent Developer's Guide v11.1.0 (53-1002169-01, May 2011)

112 Brocade Network Advisor SMI Agent Developer’s Guide
53-1002169-01
Alert indications
4
BRDC6 SNMP traps turned on by Track Change
On was turned off.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD6
How to trigger: Use the trackchangesset
CLI command to turn off the SNMP traps.
NOTE: BRCD6 indication is supported
only for FOS switches and is not
delivered if SNMP registration is
failed.
AlertingManagedElement COP of Brocade_Switch
AlertingElementFormat COP
AlertType Other
OtherAlertType Switch Alert
Aler tSubType Track Change Off
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message Alert configuration for
login, logout, orconfig
updates was turned OFF
for Switch <WWN>
MessageArguments WWN = string Switch
WWN
BRCD7 The element (port) identified by
AlertingManagedElement is up.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and
MessageID=BRCD7
How to trigger: Telnet to the switch and
run the CLI portenable portnumber to
enable a connected port, such as an
E_Port, F_Port, or L_Port.
AlertingManagedElement COP of
Brocade_SwitchFCPort
AlertingElementFormat COP
AlertType Other
OtherAlertType Port Alert
AlertSubType Up
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message Port <PortWWN> of
Switch <SwitchWWN> is
up
MessageArguments SwitchFCPort WWN
Switch WWN
TABLE 14 Supported alert indications (Continued)
Message ID Trigger Property Value