Alert indications
4
BRCD51 Successful recovery from a faulty
condition.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD51
NOTE: BRCD51 indication is supported
for the Environment, Port, and
E_Port Fabric Watch classes.
Ignore the Fabric Watch
indications for non-supported
Fabric Watch classes (GBIC or
SFP, Fabric, F and FL Port, SAM,
Security), as they are not
supported.
BRCD51 is supported in switches
running Fabric OS v6.1.0 and
later.
AlertingManagedElement COP of Brocade_Switch
AlertingElementFormat COP
AlertType Other Alert
OtherAlertType Fabric Watch
AlertSubType Threshold In Between
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Fabric WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message Fabric Watch Threshold
In Between
MessageArguments N/A
BRCD52 A counter value between two sample
periods has changed.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD52
NOTE: BRCD52 indication is supported
for the Environment, Port, and
E_Port Fabric Watch classes.
Ignore the Fabric Watch
indications for non-supported
Fabric Watch classes (GBIC or
SFP, Fabric, F/FL Port, SAM,
Security), as they are not
supported.
BRCD52 is supported in switches
running Fabric OS v6.1.0 and
later.
AlertingManagedElement COP of Brocade_Switch
AlertingElementFormat COP
AlertType Other Alert
OtherAlertType Fabric Watch
AlertSubType Threshold Change
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message Fabric Watch Threshold
Changed
MessageArguments N/A
TABLE 14 Supported alert indications (Continued)
Message ID Trigger Property Value