Brocade Troubleshooting and Diagnostics Guide v6.1.0 (53-1000853-01, June 2008)

Fabric OS Troubleshooting and Diagnostics Guide 99
53-1000853-01
Equipment status
12
Equipment status
You can display status for fans, power supply, and temperature.
NOTE
The number of fans, power supplies, and temperature sensors depends on the switch type. For
detailed specifications on these components, refer to the switch hardware reference manual. The
specific output from the status commands varies depending on the switch type.
Displaying the status of the fans
1. Connect to the switch and log in as admin.
2. Enter the fanShow command:
brcd5300:admin> fanshow
Fan 1 is Absent
Fan 2 is Ok, speed is 6553 RPM
Fan 3 is Ok, speed is 6367 RPM
The possible status values are:
OK—Fan is functioning correctly.
Absent—Fan is not present.
Below minimum—Fan is present but rotating too slowly or stopped.
Above minimum—Fan is rotating too quickly.
Unknown—Unknown fan unit installed.
FAULTY—Fan has exceeded hardware tolerance.
Displaying the status of a power supply
1. Connect to the switch and log in as admin.
2. Enter the psShow command:
brcd5300:admin> psshow
Power Supply #1 is OK
V10645,TQ2Z6452916 ,60-0300031-02, B, QCS ,DCJ3001-02P , A,TQ2Z64529
Power Supply #2 is faulty
V10704, TQ2J7040124 ,60-0300031-02, B,CHRKE,SP640-Y01A ,C ,TQ2J7040
The possible status values are:
OK—Power supply functioning correctly.
loss sig Loss of signal
frjt Frames rejected with F_RJT
fbsy Frames busied with F_BSY
TABLE 17 Error summary description (Continued)
Error type Description