53-1000437-01 15 June 2007 Fabric OS Message Reference Supporting Fabric OS v5.3.
Copyright © 2007, Brocade Communications Systems, Incorporated. ALL RIGHTS RESERVED. 53-1000437-01 Brocade, the Brocade B weave logo, Secure Fabric OS, and Brocade are registered trademarks and Tapestry is a trademark of Brocade Communications Systems, Inc., in the United States and/or in other countries. FICON, IBM BladeCenter are registered trademarks of IBM Corporation in the U.S. and other countries.
Document History The following table lists all versions of the Brocade Fabric OS Message Reference. Document Title Publication Number Summary of Changes Publication Date Diagnostic and System Error Message Reference v3.0, v4.0 53-0000210-02 First release March 2002 Diagnostic and System Error Message Reference v3.1.0 53-0000511-04 Major content reorganization June 2003 Diagnostic and System Error Message Reference v4.1.
iv Fabric OS Message Reference 53-1000437-01
Contents About This Document How This Document Is Organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii Supported Hardware and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii What’s New in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xlviii Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xlviii Additional Information . . . . . . . . . . . .
System Module Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Section I RASLog Messages Section II Audit Log Messages Chapter 2 AG System Messages AG-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 AG-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 AG-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTH-1012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AUTH-1013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AUTH-1014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AUTH-1016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AUTH-1017. . . . . . . .
BL-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 BL-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 BL-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 BL-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 BL-1008 . .
Chapter 7 BM System Messages BM-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 BM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 BM-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 BM-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EM-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 EM-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 EM-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 EM-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 EM-1010 . . . . . .
EM-1059 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EM-1060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EM-1061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EM-1062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 EM-1063 . . . . . .
FABR-1024. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 FABR-1029. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 FABR-1030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 FABR-1031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 FABR-1032. . . . . . . .
Chapter 20 FCR System Messages FCR-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 FCR-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 FCR-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 FCR-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCR-1039. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127 FCR-1040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127 FCR-1041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127 FCR-1042. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128 FCR-1043. . . . . . . . . .
FICU-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140 FICU-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140 FICU-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 FICU-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 FICU-1009 . . . . . . . .
Chapter 27 FW System Messages FW-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 FW-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 FW-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156 FW-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FW-1117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167 FW-1118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 FW-1119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 FW-1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 FW-1121 . . . . . . . . . .
FW-1173 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 FW-1174. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 FW-1175 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 FW-1176. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 FW-1177 . . . . . . . . .
FW-1250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193 FW-1251 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193 FW-1272 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194 FW-1273 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194 FW-1274. . . . . . . . . . .
FW-1327 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205 FW-1328 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206 FW-1329 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206 FW-1330 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206 FW-1331 . . . . . . . . . .
FW-1364 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220 FW-1365 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220 FW-1366 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220 FW-1367 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221 FW-1368 . . . . . . . . . .
FW-1441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232 FW-1442 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232 FW-1443 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232 FW-1444 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233 FW-1445 . . . . . . . . . .
HIL-1301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246 HIL-1302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246 HIL-1303 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246 HIL-1304 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246 HIL-1305 . . . . . . . .
HTTP-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259 HTTP-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259 Chapter 34 IBD System Messages IBD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261 Chapter 35 IBPD System Messages IBPD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISNS-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 ISNS-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 ISNS-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 ISNS-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 ISNS-1008 . . . . . . . .
Chapter 46 MPTH System Messages MPTH-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 MPTH-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 MPTH-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 Chapter 47 MQ System Messages MQ-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PDM-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304 PDM-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304 PDM-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304 PDM-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305 PDM-1009 . . . . . . . . . . . .
Chapter 56 PSWP System Messages PSWP-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319 PSWP-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319 PSWP-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319 Chapter 57 RAS System Messages RAS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 62 SCN System Messages SCN-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .333 Chapter 63 SEC System Messages SEC-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335 SEC-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335 SEC-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC-1051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346 SEC-1052. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346 SEC-1053. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346 SEC-1054. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347 SEC-1055. . . . . . . . . .
SEC-1095. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .358 SEC-1096. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .358 SEC-1097. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .358 SEC-1098. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .359 SEC-1099. . . . . . . . . .
SEC-1155. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .370 SEC-1156. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .370 SEC-1157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .370 SEC-1158. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371 SEC-1159. . . . . . . . . .
SEC-1198. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .381 SEC-1199. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382 SEC-1200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382 SEC-1201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382 SEC-1202 . . . . . . . . . .
SEC-1328. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393 SEC-1329. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393 SEC-1330. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393 SEC-1331. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SULB-1031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 SULB-1033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 SULB-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 SULB-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 SULB-1036 . . . . . . . . . . .
TRCE-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .422 TRCE-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423 TRCE-1007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423 TRCE-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .423 TRCE-1009. . . . . . . . . . . .
WEBD-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438 WEBD-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438 WEBD-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .439 Chapter 76 ZOLB System Messages ZOLB-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZONE-1037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .454 ZONE-1038 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .454 ZONE-1039 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .454 ZONE-1040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .455 ZONE-1041 . . . . . . . . . . . . .
SEC-3008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .467 SEC-3009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .468 SEC-3010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .468 SEC-3011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .468 SEC-3012. . . . . . . . . . .
Chapter 83 AUDIT SULB System Messages SULB-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .481 SULB-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .481 SULB-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .481 SULB-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZONE-3017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .498 ZONE-3018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .499 ZONE-3019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .499 ZONE-3020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .499 ZONE-3021 . . . . . . . . . . . . .
xlii Fabric OS Message Reference 53-1000437-01
About This Document This document is a system message reference manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. “About This Document” contains the following sections: • • • • • • • How This Document Is Organized . . . . . . . . . . . . . . xlvii Supported Hardware and Software . . . . . . . . . . . . . xlvii What’s New in This Document . . . . . . . . . . . . . . . . . xlviii Document Conventions . . . . . . . . . . . . . . . . . . . . . .
• Brocade 48000 director • FA4-16 blade • FC10-6 blade In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Fabric OS v5.3.0, documenting all possible configurations and scenarios is beyond the scope of this document.
bold text Identifies command and method names Identifies graphical user interface (GUI) elements Identifies keywords and operands Identifies text to enter at the GUI or command line interface (CLI) italic text Provides emphasis Identifies variables Identifies paths and Internet addresses Identifies document titles Identifies class properties code text Identifies CLI output Identifies syntax examples For readability, command names in the narrative portions of this guide are presented in mixed lettercas
NOTE Go to http://www.brocade.com and click Brocade Connect to register at no cost for a user ID and password.
ISL Trunking Brocade® ISL Trunking is an optional software product available for all Brocade 2 and 4 Gbit/sec Fibre Channel switches and directors. This technology is ideal for optimizing performance and simplifying the management of multi-switch SAN fabrics containing Brocade 1, 2, and 4 Gbit/sec switches and directors. When two or more adjacent ISLs are used to connect two switches, the switches automatically group the ISLs into a single logical ISL, or “trunk.
- Switch operating system version Error numbers and messages received supportSave command output Detailed description of the problem and specific questions Description of any troubleshooting steps already performed and results Serial console and telnet session logs syslog message logs 2.
Chapter Introduction to System Messages 1 This guide supports Fabric OS v5.3.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability log (RASLog) or AUDIT, and then alphabetically by module name. A module is a subsystem in the Fabric OS. Each module generates a set of numbered messages.
1 Overview of System Messages • Messages are numbered sequentially from 1 to 2,147,483,647 (0x7ffffff). The sequence number will continue to increase beyond the storage limit of 1024 messages. The sequence number can be reset to 1 using the errClear command. The sequence number is persistent across power cycles and switch reboots. • By default, the errDump and errShow commands display all of the system error messages.
Overview of System Messages 1 Fabric OS v5.3.
1 Viewing and Configuring System Message Logs The system console displays system messages, Audit messages (if enabled) and panic dump messages. These messages are mirrored to the system console; they are always saved in one of the system logs. You can filter messages that appear on the system console by severity using the errFilterSet command. All messages are still sent to the system message log and syslog (if enabled). PORT LOGS The Fabric OS maintains an internal log of all port activity.
Viewing and Configuring System Message Logs TABLE 2 1 Commands for Viewing or Configuring the System Parameters and Logs Command Description agtCfgDefault Resets the SNMP recipients to default values. agtCfgSet Modifies the SNMP agent configuration. agtCfgShow Displays the current SNMP agent configuration. auditCfg Configures the audit message log. auditShow Modifies and displays audit log filter configuration. diagPost Set or display diagnostic POST (Power-On Self-Test) configuration.
1 Viewing and Configuring System Message Logs TABLE 2 Commands for Viewing or Configuring the System Parameters and Logs (Continued) Command Description supportFfdc Enables and disables FFDC (first failure data capture). supportSave Collects RASLog, trace files, and supportShow (active CP only) information for the local CP and then transfers the files to an FTP server. The operation can take several minutes. supportShow Executes a list of diagnostic and error display commands.
Viewing and Configuring System Message Logs 1 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible. Reason: Configured port speed. 2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP rejected by the other switch 2004/07/28-17:05:06, [FW-1050], 5,, WARNING, switch, Sfp Supply Voltage 0, is below low boundary(High=3600, Low=3150). Current value is 0 mV.
1 Reading a RAS System Message Dazzler3850:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: Dazzler3850:admin> auditcfg --enable Audit filter is enabled. 4. Configure up to six syslog servers to receive the audit events that will be generated through syslog (procedure will vary depending on server type). 5. Configure syslog on the switch to point to the configured servers’ IP addresses. Dazzler3850:admin> syslogdipadd 10.
Reading a RAS System Message TABLE 3 1 System Message Field Description (Continued) Example Variable Name Description 4 Sequence Number Represents the error message position in the log. When a new message is added to the log, this number is incremented by 1. When this message reaches the last position in the error log, and becomes the oldest message in the log, it is deleted when a new message is added.
1 Reading a RAS System Message AUDIT, 2005/12/10-09:54:03, [SEC-1000], WARNING, SECURITY, JohnSmith/root/192.168.132.10/Telnet/CLI, Domain A/JohnsSwitch, , Incorrect password during login attempt. The fields in the error message are described in table below. TABLE 4 10 Audit Message Field Description Example Variable Name Description AUDIT Audit flag Identifies the message as an Audit message.
Responding to a System Message 1 MESSAGE SEVERITY LEVELS There are four levels of severity for messages, ranging from Critical (1) to Info (4). In general, the definitions are wide ranging and are to be used as general guidelines for troubleshooting. For all cases, you should look at each specific error message description thoroughly before taking action. System messages have the following severity levels.
1 Responding to a System Message GATHERING INFORMATION ABOUT THE PROBLEM Common steps and questions to ask yourself when troubleshooting a system message are as follows: 1. What is the current Fabric OS level? 2. What is the switch hardware version? 3. Is the switch operational? 4. Assess impact and urgency: - Is the switch down? Is it a standalone switch? How large is the fabric? Is the fabric redundant? 5. Run the errDump command on each logical switch. 6.
Responding to a System Message 1 The software watchdog process (SWD) is responsible for monitoring daemons critical to the function of a healthy switch. The SWD holds a list of critical daemons that ping the SWD periodically at a predetermined interval defined for each daemon. The ping interval is set at 133 seconds, with the exception of the Fabric Watch daemon and the IP storage demon, which ping the SWD every 333 seconds. (For a complete listing of daemons, see Table 5, KSWD.
1 System Module Descriptions System Module Descriptions Table 5 provides a summary of the system modules for which messages are documented in this reference guide; the system modules are listed alphabetically by name. TABLE 5 14 System Module Descriptions System Module Description AG Access Gateway allows multiple hosts (or HBAs) to access the fabric using fewer physical ports.
System Module Descriptions TABLE 5 1 System Module Descriptions (Continued) System Module Description FICU The FICON-CUP daemon handles communication with fibre connectivity (FICON) on IBM FICON storage devices. Errors to this module are usually initiation errors or indications that FICON-CUP prerequisites have not been met, such as a license key, core process ID (PID), and secure mode on the fabric. FKLB Fabric OS I/O kernel library module.
1 System Module Descriptions TABLE 5 16 System Module Descriptions (Continued) System Module Description KSWD The kernel software watchdog (KSWD) watches daemons for unexpected terminations and “hang” conditions and informs the HAM module to take corrective actions such as failover or reboot.
System Module Descriptions TABLE 5 1 System Module Descriptions (Continued) System Module Description MS The Management Service enables the user to obtain information about the Fibre Channel fabric topology and attributes by providing a single management access point. MS provides for both monitoring and control of the following areas: Fabric Configuration Server. Provides for the configuration management of the fabric. Unzoned Name Server.
1 System Module Descriptions TABLE 5 System Module Descriptions (Continued) System Module Description SNMP Simple Network Management Protocol is a universally supported low-level protocol that allows simple get, get next, and set requests to go to the switch (acting as an SNMP agent). It also allows the switch to send traps to the defined and configured management station. Brocade switches support six management entities that can be configured to receive these traps.
Section RASLog Messages This section provides the RASLog messages, including: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . 25 AUTH System Messages . . . . . . . . . . . . . . . . . . . . . . . 31 BKSW System Messages . . . . . . . . . . . . . . . . . . . . . . 45 BL System Messages . . . . . . . . . . . . . . . . . . . . . . . . . 47 BLL System Messages . . . . . . . . . . . . . . . . . . . . . . . .
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • IBPD System Messages . . . . . . . . . . . . . . . . . . . . . . 263 ICPD System Messages . . . . . . . . . . . . . . . . . . . . . . 265 IPAD System Messages . . . . . . . . . . . . . . . . . . . . . . 269 IPS System Messages . . . . . . . . . . . . . . . . . . . . . . . 271 ISCS System Messages . . . . . . . . . . . . . . . . . . . . . . 273 ISNS System Messages . . . . . . . . . . . . . . . . . . . . . .
• • • • UPTH System Messages. . . . . . . . . . . . . . . . . . . . . . 435 WEBD System Messages . . . . . . . . . . . . . . . . . . . . . 437 ZOLB System Messages . . . . . . . . . . . . . . . . . . . . . . 441 ZONE System Messages . . . . . . . . . . . . . . . . . . . . .
Section Audit Log Messages This section provides the Audit messages, including: • • • • • • • AUDIT AUTH System Messages . . . . . . . . . . . . . . . . 457 AUDIT CONF System Messages . . . . . . . . . . . . . . . . 461 AUDIT HTTP System Messages . . . . . . . . . . . . . . . . 463 AUDIT SEC System Messages . . . . . . . . . . . . . . . . . 465 AUDIT SNMP System Messages. . . . . . . . . . . . . . . . 479 AUDIT SULB System Messages . . . . . . . . . . . . . . . . 481 AUDIT ZONE System Messages . . . . .
Chapter AG System Messages 2 AG-1001 Message , [AG-1001], ,, ERROR, , N_Port ID virtualization (NPIV) is not supported by fabric port connected to port . Probable Cause N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access Gateway is connected.
2 AG-1004 Severity WARNING AG-1004 Message , [AG-1004], ,, ERROR, , Invalid response to fabric login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates that the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Please check the configuration of the fabric switch.
AG-1008 Recommended Action Severity 2 Check the connectivity between the Access Gateway N_Port and the fabric switch port. WARNING AG-1008 Message , [AG-1008], ,, WARNING, , Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates that the fabric switch management server did not accept the N_Port Login (PLOGI) request sent by the Access Gateway.
2 AG-1011 AG-1011 Message , [AG-1011], ,, WARNING, , Sending FDISC failed on N_Port . Probable Cause Indicates failure of sending the discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Please check the configuration of the fabric switch connected to the Access Gateway.
AG-1015 Severity 2 INFO AG-1015 Message , [AG-1015], ,, WARNING, , Unable to find online N_Ports to connect to the fabric. Probable Cause Either no other N_Port is configured or all N_Ports are currently offline. Recommended Action Please check whether or not any other N_Port is configured.
2 AG-1018 Recommended Action Severity 30 Run switchShow to display the status of all ports in the system. Run portCfgShow to display a list of ports currently configured as N_Port(s). Ensure that the host is connected to an F_port.
Chapter AUTH System Messages 3 AUTH-1001 Message , [AUTH-1001], ,, INFO, , has been successfully completed. Probable Cause Indicates that the secret database operation has been updated using the secAuthSecret command. The values for Operation type can be “set” or “remove”. Recommended Action No action is required.
3 AUTH-1004 AUTH-1004 Message , [AUTH-1004], ,, ERROR, , Failed to set type to . Probable Cause Indicates that the authUtil command has failed to set the authentication configuration value. The data type is either “authentication type”, “DH group type”, or “policy type”. Recommended Action Retry the authUtil command.
AUTH-1008 Recommended Action Severity 3 Run the authUtil command to make sure the local switch supports the specified protocols: Fibre channel authentication protocol (FCAP) or Diffie Hellman - challenge handshake authentication protocol (DH-CHAP). ERROR AUTH-1008 Message , [AUTH-1008], ,, ERROR, , No security license, operation failed. Probable Cause Indicates that the switch does not have a security license.
3 AUTH-1012 AUTH-1012 Message , [AUTH-1012], ,, WARNING, , Authentication is rejected: port explain reason . Probable Cause Indicates that an authentication is rejected because the remote entity does not support authentication. Recommended Action Make sure the entity at the other end of the link supports authentication.
AUTH-1017 3 Probable Cause This may relate to an internal failure. Recommended Action Copy the message, collect switch information using the supportShow command, and contact your switch service provider. Severity ERROR AUTH-1017 Message , [AUTH-1017], ,, ERROR, , Invalid value to start authentication request: port , operation code . Probable Cause Indicates an internal problem with the Secure Fabric OS.
3 AUTH-1022 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-1022 Message , [AUTH-1022], ,, ERROR, , Failed to extract from payload: port . Probable Cause Indicates that the authentication process failed to extract a particular value from the receiving payload.
AUTH-1025 Severity 3 ERROR AUTH-1025 Message , [AUTH-1025], ,, ERROR, , Failed to get during : port . Probable Cause Indicates that the authentication process failed to get the expected information during the specified authentication phase. Recommended Action Usually this problem is transient. The authentication might fail.
3 AUTH-1028 Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message Probable Cause , [AUTH-1028], ,, ERROR, , Failed to allocate for : port .
AUTH-1031 3 Probable Cause Indicates the receiving payload does not have valid message code for a particular authentication phase. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
3 AUTH-1034 Probable Cause Indicates that an entity was not configured in the switch connection control (SCC) policy and tried to connect to the port. Recommended Action Add the entity's world-wide name (WWN) to the SCC policy and reinitialize authentication by using the portDisable and portEnable commands or the switchDisable and switchEnable commands.
AUTH-1037 3 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1037 Message , [AUTH-1037], ,, ERROR, , Failed to response for : init_len , resp_len , port .
3 AUTH-1040 Recommended Action Severity Correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port using the portEnable command. ERROR AUTH-1040 Message , [AUTH-1040], ,, INFO, , Reject authentication on port , because switch authentication policy is set to OFF. Probable Cause Indicates that the local switch has rejected the authentication because the switch policy is turned off.
AUTH-1043 Recommended Action 3 Check the connection port for a possible security attack. Check the shared secrets using secAuthSecret and reinitialize authentication using the portDisable and portEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
3 44 AUTH-1044 Fabric OS Message Reference 53-1000437-01
Chapter BKSW System Messages 4 BKSW-1003 Message Probable Cause , [BKSW-1003], ,, WARNING, , kSWD: . Indicates a warning state within the system. A critical application error was reported in the watchdog subsystem. This message is used to convey information that might be of interest to the customer regarding the state of the system. Refer to the string at the end of the error message for specific information.
4 46 BKSW-1003 Fabric OS Message Reference 53-1000437-01
Chapter BL System Messages 5 BL-1000 Message , [BL-1000], ,, INFO, , Initializing ports... Probable Cause Indicates that the switch has started initializing the ports. Recommended Action No action is required. Severity INFO BL-1001 Message , [BL-1001], ,, INFO, , Port initialization completed. Probable Cause Indicates that the switch has completed initializing the ports.
5 BL-1003 Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade fault messages precede and follow this error, providing more information. See other error messages for recommended action. If the message persists, replace the blade. Severity CRITICAL BL-1003 Message , [BL-1003], , FFDC, CRITICAL, , Faulting blade in slot . Probable Cause Indicates a faulty blade in the specified slot number.
BL-1007 5 Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the standby control processor (CP) blade connected to the active CP blade has experienced transitory problems. Recommended Action Use the haShow command to verify that the standby CP is healthy. If the standby CP was removed or faulted by user intervention, no action is required.
5 BL-1010 Probable Cause Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
BL-1012 5 BL-1012 Message , [BL-1012], ,, ERROR, , bport port int. is disabled. status=0x Port will be re-enabled in 1 minute. Probable Cause Indicates that the port generated an excessive number of interrupts that might prove unrecoverable to the switch operation. The port is disabled to prevent the control processor (CP) from becoming too busy.
5 BL-1015 Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot the switch. Run the systemVerification command to determine if there is a hardware error. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
BL-1017 Recommended Action 5 Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade.
5 BL-1020 BL-1020 Message , [BL-1020], ,, CRITICAL, , Switch timed out initializing the chips. Probable Cause Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
BL-1023 5 BL-1023 Message , [BL-1023], ,, CRITICAL, , Blade in slot was reset before blade init completed. As a result the blade is faulted. Probable Cause Indicates that the blade was reset before the initialization completed. Recommended Action Reboot or power cycle the blade. Severity If the message persists, replace the blade.
5 BL-1027 Recommended Action Severity Collect supportSave information, then reboot switch and run the diagPost command to ensure Power-On Self-Test (POST) is enabled. If problem persists, replace switch. CRITICAL BL-1027 Message , [BL-1027], ,, CRITICAL, , Blade in slot faulted, boot failed; status 0x 0x<1250 0 boot status> 0x<1250 1 boot status>. Probable Cause Indicates that the blade failed to boot properly.
BL-1030 5 BL-1030 Message , [BL-1030], ,, INFO, , All GigE/FCIP Virtualization/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GigE/Fibre Channel over IP (FCIP)/Virtualization data elements / FC Fastwrite ports were reset.
5 BL-1034 Probable Cause Indicates that the system timed out while waiting for disable messages from the user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the message persists, replace the blade. Refer to the Fabric OS Command Reference for more information on the systemVerification command.
Chapter BLL System Messages 6 BLL-1000 Message Probable Cause , [BLL-1000], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Indicates that a blade regulation problem was reported on the specified slot number. The blade is faulted.
6 BLL-1000 If the message persists, replace the blade.
Chapter BM System Messages 7 BM-1001 Message Probable Cause , [BM-1001], ,, ERROR, , BM protocol version in slot . Indicates that the software running on the CP cannot communicate with the AP blade in the indicated slot, in order to determine AP blade's firmware version. This can be due to one of the following: • • Recommended Action Severity The CP blade is running a later version than the AP blade.
7 BM-1004 Recommended Action Severity Use the slotPoweroff and slotPoweron commands or reseat the affected blade. On the Brocade 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. WARNING BM-1004 Message Probable Cause Recommended Action Severity , [BM-1004], ,, INFO, , Blade firmware on slot < Slot > is not consistent with system firmware .
BM-1007 7 BM-1007 Message , [BM-1007], ,, INFO, , Clearing EX/VEX/FC port configuration for all ports for blade in slot . Probable Cause The specified blade was detected for the first time after an FR4-18i was previously configured in the same slot. The new blade requires the specified port configurations to be cleared. Recommended Action The blade ports are cleared automatically. No action is required.
7 BM-1055 Recommended Action Severity No action is required. The blade will automatically download the updated firmware. INFO BM-1055 Message , [BM-1055], ,, WARNING, , Firmwaredownload timed-out for AP. Faulting switch. Probable Cause The firmwareDownload command on the application processor (AP) blade failed. Recommended Action Use the slotPoweroff and slotPoweron commands or reseat the affected blade.
Chapter CDR System Messages 8 CDR-1001 Message , [CDR-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable between peer ports, or the port speed configuration does not match the capability of the SFP. Recommended Action Verify that you are using compatible SFPs on the peer ports.
8 CDR-1004 Severity CRITICAL CDR-1004 Message , [CDR-1004], , FFDC, ERROR, , , : invalid DMA ch pointer, chan:, good_addr:0x, bad_addr:0x. Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Action Whenever this error occurs, reboot the system at the next maintenance window.
Chapter CER System Messages 9 CER-1001 Message , [CER-1001], ,, ERROR, , HA Sync broken, since standby Advanced Performance Tuning module does not support FICON Management Server (FMS). Probable Cause Indicates that the high-availability (HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP.
9 68 CER-1001 Fabric OS Message Reference 53-1000437-01
Chapter CONF System Messages 10 CONF-1000 Message , [CONF-1000], , AUDIT, INFO, , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed successfully. The message string that follows is a description of the class of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description.
10 CONF-1021 CONF-1021 Message , [CONF-1021], ,, INFO, , configUpload not permitted . Probable Cause There are many possible causes. Recommended Action Check the error log for a possible cause. Please correct the error and upload the configuration again.
Chapter EM System Messages 11 EM-1001 Message , [EM-1001], , FFDC, CRITICAL, , is over heating: Shutting down. Probable Cause Indicates that a field-replaceable unit (FRU) is shutting down due to overheating. This is typically due to a faulty fan but can also be caused by the switch environment. Recommended Action Verify that the location temperature is within the operational range of the switch.
11 EM-1004 Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. On the Brocade 24000 and 48000, replace the specified FRU. For the Brocade 3900, replace the motherboard FRU. For the Brocade 200E, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, and AP7600, replace the switch.
EM-1006 11 EM-1006 Message , [EM-1006], , FFDC, CRITICAL, , has faulted. Sensor(s) below minimum limits. Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade is being shut down for environmental reasons; the voltage is too low. Recommended Action If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the blade.
11 EM-1009 EM-1009 Message , [EM-1009], , FFDC, CRITICAL, , powered down unexpectedly. Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the specified field-replaceable unit (FRU). This might indicate a hardware malfunction in the FRU. Recommended Action Try reseating the FRU. If the message persists, replace the FRU.
EM-1012 11 EM-1012 Message , [EM-1012], , FFDC, CRITICAL, , failed state transition, FRU faulted. Probable Cause Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch.
11 EM-1015 EM-1015 Message , [EM-1015], ,, WARNING, , Warm recovery failed (). Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot. Recommended Action Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the problem.
EM-1018 11 EM-1018 Message , [EM-1018], , FFDC, CRITICAL, , CP blade in slot failed to retrieve current chassis type (//0x). Probable Cause Indicates that there was a failure to read the chassis type from the system. Recommended Action Verify that the control processor (CP) blade is operational and is properly seated in its slot.
11 EM-1029 EM-1029 Message , [EM-1029], ,, WARNING, , , a problem occurred accessing a device on the I2C bus (). Operational status () not changed, access is being retried. Probable Cause Indicates that the I2C bus had problems and a timeout occurred. Recommended Action This is often a transient error. Watch for the EM-1048 message, which indicates that the problem has been resolved.
EM-1034 11 EM-1034 Message , [EM-1034], ,, ERROR, , set to faulty, rc=. Probable Cause Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified reason. Recommended Action Try reseating the FRU. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command.
11 EM-1036 EM-1036 Message Probable Cause , [EM-1036], ,, WARNING, , is not accessible. Indicates that the specified field-replaceable unit (FRU) does not seem to be present on the switch. If the FRU is a world-wide name (WWN) card, then default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch.
EM-1042 11 EM-1042 Message , [EM-1042], ,, WARNING, , Important FRU header data for is not valid). Probable Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU header-derived information. This could mean that the FRU header was corrupted or read incorrectly or corrupted in the object database, which contains information about all FRUs. Recommended Action Try reseating the FRU.
11 EM-1045 EM-1045 Message , [EM-1045], ,, WARNING, , is being powered . Probable Cause Indicates that an automatic power adjustment is being made because of the (predicted) failure of a power supply or the insertion or removal of a port blade. If new_state is On, a port blade is being powered on because more power is available (either a power supply was inserted or a port blade was removed or powered down).
EM-1048 11 EM-1048 Message , [EM-1048], ,, INFO, , I2C access recovered: state Probable Cause Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available again. Recommended Action The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is displayed.
11 EM-1055 Severity INFO EM-1055 Message Probable Cause , [EM-1055], ,, WARNING, , : Port media incompatible. Reason: Indicates that an incompatible port media is detected. The possible causes are: • The port media is not capable of running at the configured port speed. • The port media generates too much heat to be used in the slot.
EM-1058 11 EM-1058 Message , [EM-1058], ,, WARNING, , Switch gets reset: Probable Cause The switch is automatically reset due to known resetable transient errors, such as an application-specific integrated circuit.(ASIC) parity. error. Recommended Action No action is required if the switch does not reach the reset threshold for the switch/blade.
11 EM-1062 Recommended Action Severity Please remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken, this CP must be rebooted or haSyncStart must be run successfully. Until this is done, the system will remain out of synchronization. WARNING EM-1062 Message , [EM-1062], ,, CRITICAL, , Blade in slot faulted as it exceeds the maximum support limit of blades with Blade ID in the chassis.
EM-1065 11 EM-1065 Message , [EM-1065], ,, CRITICAL, , SAS Virtualization Services are not available due to incompatiblity between the FOS and SAS versions . Probable Cause The version of either the control processor firmware (CFOS) or the blade processor firmware (BFOS) is not compatible with the Storage Application Services (SAS) or other application firmware version(s).
11 88 EM-2003 Fabric OS Message Reference 53-1000437-01
Chapter EVMD System Messages 12 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band. Recommended Action Please make sure that the specified remote domain is present in the fabric.
12 90 EVMD-1001 Fabric OS Message Reference 53-1000437-01
Chapter FABR System Messages 13 FABR-1001 Message , [FABR-1001], ,, WARNING, , port , . Probable Cause Indicates that the specified switch port is isolated because of a segmentation due to mismatched configuration parameters. Recommended Action Based on the segmentation reason displayed within the message, look for a possible mismatch of relevant configuration parameters in the switches at both ends of the link.
13 FABR-1004 Run the fabStateShow command on both the receiving and transmitting switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
FABR-1007 Recommended Action 13 In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], ,, WARNING, , IU free error, caller: .
13 FABR-1010 Recommended Action Severity The fabric daemon will discard the EFP. The system will recover through the EFP retrial process. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1010 Message , [FABR-1010], ,, WARNING, , .
FABR-1013 13 FABR-1013 Message , [FABR-1013], , FFDC, CRITICAL, , No Memory: pid= file=
13 FABR-1016 FABR-1016 Message , [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended Action No action is required. Severity WARNING FABR-1017 Message , [FABR-1017], ,, WARNING, , ficonMode is disabled. Probable Cause Indicates that FICON mode is disabled on the switch through a user interface command.
FABR-1019 13 FABR-1019 Message , [FABR-1019], , FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration (). Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the number of domains. This limit is defined by your specific value-line license key.
13 FABR-1022 FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer () started from . Probable Cause Indicates that the fabric size has exceeded the value-line limit, and the grace period counter has started. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled.
FABR-1029 13 FABR-1029 Message , [FABR-1029], ,, INFO, , Port negotiated (mode = ). Probable Cause Indicates that a different flow control mode, as described in the message, is negotiated with the port at the other end of the link. The flow control is a mechanism of throttling the transmitter port to avoid buffer overrun at the receiving port.
13 FABR-1032 FABR-1032 Message , [FABR-1032], , FFDC, WARNING, , Remote switch with domain ID and switchname running an unsupported FOS version v2.x has joined the fabric. Probable Cause Indicates that a switch with an unsupported Fabric OS version 2.x has joined the fabric. Recommended Action Remove the switch with the unsupported Fabric OS version 2.x from the fabric.
Chapter FABS System Messages 14 FABS-1001 Message , [FABS-1001], , FFDC, CRITICAL, , Probable Cause Indicates that the system is low on memory and cannot allocate more memory for new operations. This is usually an internal Fabric OS problem or file corruption. Description of memory need indicates how much memory was being requested. The value could be any whole number.
14 FABS-1005 FABS-1005 Message Probable Cause , [FABS-1005], ,, WARNING, , (= ) Indicates that an unsupported operation has been requested. This is usually an internal Fabric OS problem or file corruption. The possible values for function name and description of problem are: fabsys_write: Unsupported write operation: process xxx where "xxx" is the process ID (PID), which could be any whole number.
FABS-1007 14 FABS-1007 Message , [FABS-1007], ,, WARNING, , : Media state is invalid - status= Probable Cause Indicates that the Fabric OS has detected an invalid value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. Severity If the message persists, run the firmwareDownload command to update the firmware.
14 FABS-1010 FABS-1010 Message , [FABS-1010], ,, WARNING, , : Wrong media_event Probable Cause Indicates that the Fabric OS detected an unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. Severity If the message persists, run the firmwareDownload command to update the firmware.
FABS-1013 14 FABS-1013 Message Probable Cause , [FABS-1013], ,, ERROR, , []:Unknown blade type 0x An unrecognized type of blade has been discovered in the system. This may be caused by an incorrect FRU header, inability to read the FRU header, or the blade may not be supported by this platform or Fabric OS version. Recommended Action Verify that the blade is valid for use in this system and this version of Fabric OS.
14 106 FABS-1015 Fabric OS Message Reference 53-1000437-01
Chapter FBC System Messages 15 FBC-1001 Message , [FBC-1001], ,, ERROR, , Firmware version on AP blade is incompatible with that on the CP. Probable Cause The CP determined that the version of firmware running on the AP blade is not compatible with the version of firmware running on the CP. The AP and CP blades cannot communicate. Recommended Action The problem can be corrected by changing the version of firmware on the CP or AP blades.
15 108 FBC-1001 Fabric OS Message Reference 53-1000437-01
Chapter FCIP System Messages 16 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= Probable Cause Indicates that the hardware is not responding to a command request; possibly because it is busy. Recommended Action Retry the command.
16 110 FCIP-1000 Fabric OS Message Reference 53-1000437-01
Chapter FCMC System Messages 17 FCMC-1001 Message , [FCMC-1001], , FFDC, CRITICAL, , System is low on memory and has failed to allocate new memory. Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for an information unit (IU). Recommended Action A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP.
17 112 FCMC-1001 Fabric OS Message Reference 53-1000437-01
Chapter FCPD System Messages 18 FCPD-1001 Message Probable Cause , [FCPD-1001], ,, WARNING, , Probing failed on . Indicates that a fibre channel protocol (FCP) switch probed devices on a loop port, and the probing failed on the either the L_Port, AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF.
18 114 FCPD-1003 Fabric OS Message Reference 53-1000437-01
Chapter FCPH System Messages 19 FCPH-1001 Message Probable Cause , [FCPH-1001], , FFDC, CRITICAL, , : failed, out of memory condition Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed function call is "kmalloc_wrapper failed".
19 116 FCPH-1001 Fabric OS Message Reference 53-1000437-01
Chapter FCR System Messages 20 FCR-1001 Message , [FCR-1001], ,, INFO, , FC router proxy device in edge created at port . Probable Cause Indicates that a proxy device in the edge fabric has been imported at the specified port. Recommended Action No action is required. Severity INFO FCR-1002 Message , [FCR-1002], ,, INFO, , FC router proxy device in edge deleted at port .
20 FCR-1004 FCR-1004 Message , [FCR-1004], ,, INFO, , FC router physical devices offline at port . Probable Cause Indicates that one or more physical devices connected to the specified port have gone offline. Recommended Action Verify that the device(s) were intended to be taken offline. Severity If not, verify that the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly.
FCR-1008 Severity 20 INFO FCR-1008 Message , [FCR-1008], ,, INFO, , FC router LSAN zone created at port . Probable Cause Indicates that a logical storage area network (LSAN) zone was created at the specified port in the edge fabric. Recommended Action No action is required. Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN zone enabled at port : .
20 FCR-1012 Recommended Action Severity No action is required. INFO FCR-1012 Message , [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended Action No action is required.
FCR-1018 Recommended Action Severity 20 No action is required. INFO FCR-1018 Message , [FCR-1018], ,, ERROR, , FC router proxy device entries exhausted on port . Probable Cause Indicates that the number of proxy devices is greater than allowed by the port resource. Recommended Action Remove excess logical storage area network (LSAN) zones or devices until the number of proxy devices exported is within the range allowed by the port resource.
20 FCR-1021 To do that, perform the following steps: 1. Run portDisable to disable all the EX_Ports that got this error message. 2. Run portDisable to disable all the other EX_Ports on that FCR connected to the same edge fabrics the EX_ports disabled in step 1 are connected to. 3. Use Zoning commands on the edge fabrics, to reduce the LSAN zone entries on the edge fabrics. 4. Run portEnable on each EX_Port, one at a time, to reenable the EX_Ports, and verify that this error is not reported again.
FCR-1024 Recommended Action Severity 20 Limit the number of port WWNs required by limiting the remote edge fabric connectivity (which limits the number of translate domains). You can also limit the number of proxy devices for a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in logical storage area network (LSAN) zones.
20 FCR-1027 FCR-1027 Message , [FCR-1027], ,, INFO, , In slot port WWN roll over. Probable Cause Indicates that the port world-wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed.
FCR-1030 20 To avoid WWN conflicts, all EX_Ports attached to fabrics with highly dynamic changes to EX_Port connectivity should be disabled then reenabled. Severity INFO FCR-1030 Message , [FCR-1030], ,, INFO, , Physical device came online at fabric . Probable Cause Indicates that the physical device world-wide name (WWN) came online in the specified fabric. Recommended Action No action is required.
20 FCR-1034 Recommended Action Severity No action is required. INFO FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric. Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone fabric. Recommended Action No action is required. Severity INFO FCR-1035 Message , [FCR-1035], ,, INFO, , LSAN zone device added in the backbone fabric.
FCR-1038 Recommended Action Severity 20 No action is required. INFO FCR-1038 Message , [FCR-1038], ,, WARNING, , Total zone entries exceeded local fabric limits by entries, in zone: , zone limit: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations.
20 FCR-1042 Probable Cause Indicates that a logical storage area network (LSAN) zone device within the backbone fabric was removed. Recommended Action No action is required. Severity INFO FCR-1042 Message , [FCR-1042], ,, INFO, , LSAN zone removed in the backbone fabric. Probable Cause Indicates that a logical storage area network (LSAN) zone within the backbone fabric was removed. Recommended Action No action is required.
FCR-1049 20 FCR-1049 Message , [FCR-1049], ,, ERROR, , EX port () received an ELP command that is not supported. Probable Cause Indicates an incoming exchange link protocol (ELP) command was issued and it is not supported. Recommended Action Run the portEnable and portDisable commands to enable and disable the port. Severity If the problem persists contact your switch service provider.
20 FCR-1055 FCR-1055 Message , [FCR-1055], ,, INFO, , Switch with domain ID does not support backbone to edge imports. Probable Cause Indicates that a switch that does not support backbone-to-edge routing was detected in the backbone. Edge-to-edge routing will work, but backbone-to-edge routing might fail. Recommended Action No action is required if backbone to edge routing is not required.
FCR-1059 Recommended Action 20 Please check the switches on both ends of the link for a possible mismatch in switch or port configuration parameters such as 'Operating Mode', EDTOV, or RATOV. Run the portCfgExport command to modify the appropriate parameters on the local switch. Run the appropriate configuration command to modify the switch or port parameters on the remote switch.
20 FCR-1062 Recommended Action Severity No action is required. INFO FCR-1062 Message , [FCR-1062], ,, INFO, , Port disabled, system only supports EX/VEX_ports. Probable Cause Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Recommended Action No action is required.
FCR-1066 20 Probable Cause Indicates that another port on the switch is connected to the same edge fabric with a different fabric ID assignment. Recommended Action Change the port fabric ID to same value as the other ports connected to the edge fabric using the portCfgExport or portCfgVexport commands. Severity ERROR FCR-1066 Message , [FCR-1066], ,, ERROR, , Fabric on port has the same fabric ID as another fabric.
20 FCR-1069 Severity INFO FCR-1069 Message , [FCR-1069], ,, INFO, , The FC Routing service is enabled. Probable Cause Indicates that the FC Routing service is enabled. This is caused by either fosConfig –-enable fcr, or a configDownload with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended Action No action is required.
FCR-1072 Recommended Action Severity 20 No action is required.
20 FCR-1073 FCR-1073 Message , [FCR-1073], ,, INFO, , Switch with domain ID in fabric has lower limit of LSAN Zones supported. Probable Cause Indicates that a switch in the backbone/edge that supports different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits.
FCR-1076 20 FCR-1076 Message , [FCR-1076], ,, ERROR, , Port disabled, system only supports front domains. Probable Cause Indicates that the maximum number of supported front domains was exceeded. To enable the specified port, disable any other operational front domain and then re-enable the port. Recommended Action Make sure to remain within the maximum of supported front domains.
20 138 FCR-1076 Fabric OS Message Reference 53-1000437-01
Chapter FICU System Messages 21 FICU-1001 Message , [FICU-1001], ,, ERROR, , : config failed rc = . Probable Cause Indicates that one of the configuration management functions failed. The key variable is part of the Fabric OS configuration database and is for support use only. The error variable is an internal error number.
21 FICU-1004 Severity WARNING FICU-1004 Message Probable Cause , [FICU-1004], ,, WARNING, , : Failed to set fabric manager server (FMS) mode: conflicting PID Format:, FMS Mode:. Indicates that a process ID (PID) format conflict was encountered. The core PID format is required for fibre connectivity control unit port (FICON-CUP).
FICU-1007 Recommended Action Severity 21 Check if the FICON channel corresponding to the PID in the message is functioning correctly. WARNING FICU-1007 Message , [FICU-1007], ,, WARNING, , : Failed to allocate memory while performing . Probable Cause Indicates that memory resources are low. This might be a transient problem. Recommended Action If the message persists, check the memory usage on the switch, using the memShow command.
21 FICU-1010 FICU-1010 Message , [FICU-1010], ,, WARNING, , FMS Mode enable failed due to address conflict with port . Probable Cause Indicates that the fibre connectivity FICON Management Server mode (fmsMode) was not enabled because the specified port has an address conflict with the CUP management port is in use. Recommended Action Use the portDisable command to disable the specified port to avoid the port address conflict.
Chapter FKLB System Messages 22 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it automatically recovers after the application times the exchange out. Recommended Action No action is required.
22 144 FKLB-1001 Fabric OS Message Reference 53-1000437-01
Chapter FLOD System Messages 23 FLOD-1001 Message , [FLOD-1001], , FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link state record (LSR) type is unknown. 1-Unicast and 3-Multicast are the only two LSR header types. Recommended Action No action is required; the record is discarded.
23 FLOD-1005 FLOD-1005 Message , [FLOD-1005], ,, WARNING, , Invalid received domain ID: Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended Action No action is required; the LSR is discarded.
Chapter FSPF System Messages 24 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended Action No action is required.
24 FSPF-1005 FSPF-1005 Message , [FSPF-1005], ,, ERROR, , Wrong Section Id , should be , input port = Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID.
Chapter FSS System Messages 25 FSS-1001 Message , [FSS-1001], ,, WARNING, , Component () dropping HA data update (). Probable Cause Indicates that an application has dropped a high availability (HA) data update. Recommended Action Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed system.
25 FSS-1003 FSS-1003 Message , [FSS-1003], ,, WARNING, , Component () misused the update transaction () without marking the transaction beginning. Probable Cause Indicates that the Fabric OS state synchronization (FSS) service has dropped the update because an application has not set the transaction flag correctly.
FSS-1006 25 FSS-1006 Message , [FSS-1006], ,, WARNING, , No FSS message available Probable Cause Indicates that data is not available on the Fabric OS state synchronization (FSS) device. Recommended Action If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
25 152 FSS-1007 Fabric OS Message Reference 53-1000437-01
Chapter FSSM System Messages 26 FSSM-1002 Message , [FSSM-1002], ,, INFO, , HA State is in sync. Probable Cause Indicates that the high availability (HA) state for the active control processor (CP) is in synchronization with the HA state of the standby CP. If the standby CP is healthy, then a failover is nondisruptive. For more information on the haFailover command, refer to the Fabric OS Command Reference. Recommended Action No action is required.
26 FSSM-1004 FSSM-1004 Message , [FSSM-1004], ,, INFO, , Incompatible software version in HA synchronization. Probable Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a non-bladed system, this message is logged when the firmware upgrade/downgrade was invoked.
Chapter FW System Messages 27 FW-1001 Message , [FW-1001], ,, INFO, ,
27 FW-1003 FW-1003 Message , [FW-1003], ,, WARNING, ,
FW-1006 27 FW-1006 Message , [FW-1006], ,, WARNING, ,
27 FW-1009 FW-1009 Message , [FW-1009], ,, INFO, ,
FW-1012 27 FW-1012 Message , [FW-1012], ,, INFO, ,
27 FW-1035 FW-1035 Message , [FW-1035], ,, WARNING, ,
FW-1038 27 FW-1038 Message , [FW-1038], ,, WARNING, ,
27 FW-1041 FW-1041 Message , [FW-1041], ,, INFO, ,
FW-1044 27 FW-1044 Message , [FW-1044], ,, INFO, ,
27 FW-1047 FW-1047 Message , [FW-1047], ,, WARNING, ,
FW-1050 27 FW-1050 Message , [FW-1050], ,, WARNING, ,
27 FW-1113 FW-1113 Message , [FW-1113], ,, INFO, ,
FW-1116 27 FW-1116 Message , [FW-1116], ,, INFO, ,
27 FW-1118 FW-1118 Message Probable Cause , [FW-1118], ,, INFO, ,
FW-1120 27 FW-1120 Message Probable Cause , [FW-1120], ,, INFO, ,
27 FW-1123 FW-1123 Message , [FW-1123], ,, INFO, ,
FW-1126 27 FW-1126 Message Probable Cause , [FW-1126], ,, INFO, ,
27 FW-1128 FW-1128 Message Probable Cause , [FW-1128], ,, INFO, ,
FW-1131 27 FW-1131 Message , [FW-1131], ,, INFO, ,
27 FW-1134 FW-1134 Message , [FW-1134], ,, INFO, ,
FW-1137 27 FW-1137 Message , [FW-1137], ,, INFO, ,
27 FW-1140 FW-1140 Message , [FW-1140], ,, INFO, ,
FW-1162 27 FW-1162 Message , [FW-1162], ,, WARNING, , ,
27 FW-1165 Severity INFO FW-1165 Message , [FW-1165], ,, INFO, , ,
FW-1168 27 FW-1168 Message , [FW-1168], ,, INFO, , ,
27 FW-1171 FW-1171 Message , [FW-1171], ,, INFO, , ,
FW-1174 27 FW-1174 Message , [FW-1174], ,, WARNING, , ,
27 FW-1177 FW-1177 Message , [FW-1177], ,, INFO, , ,
FW-1180 27 FW-1180 Message , [FW-1180], ,, INFO, , ,
27 FW-1183 FW-1183 Message , [FW-1183], ,, INFO, , ,
FW-1186 27 FW-1186 Message , [FW-1186], ,, INFO, , ,
27 FW-1189 FW-1189 Message , [FW-1189], ,, INFO, , ,
FW-1192 27 FW-1192 Message , [FW-1192], ,, INFO, , ,
27 FW-1195 FW-1195 Message , [FW-1195], ,, INFO, , ,
FW-1218 Recommended Action Severity 27 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1218 Message , [FW-1218], ,, WARNING, ,
27 FW-1240 FW-1240 Message , [FW-1240], ,, INFO, ,
FW-1243 27 FW-1243 Message , [FW-1243], ,, INFO, ,
27 FW-1246 FW-1246 Message , [FW-1246], ,, INFO, ,
FW-1249 27 FW-1249 Message , [FW-1249], ,, INFO, ,
27 FW-1272 FW-1272 Message , [FW-1272], ,, INFO, ,
FW-1275 27 FW-1275 Message , [FW-1275], ,, INFO, ,
27 FW-1298 FW-1298 Message , [FW-1298], ,, WARNING, ,
FW-1301 27 FW-1301 Message , [FW-1301], ,, INFO, ,
27 FW-1304 FW-1304 Message , [FW-1304], ,, INFO, ,
FW-1307 27 FW-1307 Message , [FW-1307], ,, INFO, ,
27 FW-1310 FW-1310 Message , [FW-1310], ,, WARNING, ,
FW-1313 27 FW-1313 Message , [FW-1313], ,, INFO, ,
27 FW-1316 FW-1316 Message , [FW-1316], ,, INFO, ,
FW-1319 27 FW-1319 Message , [FW-1319], ,, INFO, ,
27 FW-1322 FW-1322 Message , [FW-1322], ,, WARNING, ,
FW-1325 27 FW-1325 Message , [FW-1325], ,, INFO, ,
27 FW-1328 FW-1328 Message , [FW-1328], ,, INFO, ,
FW-1331 27 FW-1331 Message , [FW-1331], ,, INFO, ,
27 FW-1334 FW-1334 Message , [FW-1334], ,, WARNING, ,
FW-1337 27 FW-1337 Message , [FW-1337], ,, INFO, ,
27 FW-1339 FW-1339 Message , [FW-1339], ,, INFO, ,
FW-1342 27 FW-1342 Message , [FW-1342], ,, WARNING, ,
27 FW-1345 FW-1345 Message , [FW-1345], ,, INFO, ,
FW-1347 27 FW-1347 Message , [FW-1347], ,, INFO, ,
27 FW-1349 FW-1349 Message , [FW-1349], ,, INFO, ,
FW-1351 27 FW-1351 Message , [FW-1351], ,, INFO, ,
27 FW-1353 FW-1353 Message , [FW-1353], ,, INFO, ,
FW-1355 27 FW-1355 Message , [FW-1355], ,, INFO, ,
27 FW-1358 FW-1358 Message , [FW-1358], ,, WARNING, ,
FW-1361 27 FW-1361 Message , [FW-1361], ,, INFO, ,
27 FW-1364 FW-1364 Message , [FW-1364], ,, INFO, ,
FW-1367 27 FW-1367 Message , [FW-1367], ,, INFO, ,
27 FW-1370 FW-1370 Message , [FW-1370], ,, WARNING, ,
FW-1373 Severity 27 INFO FW-1373 Message , [FW-1373], ,, INFO, ,
27 FW-1376 Recommended Action Severity No action is required. INFO FW-1376 Message , [FW-1376], ,, INFO, ,
FW-1379 27 Probable Cause Indicates that the number of illegal commands has risen above the high boundary. This counter tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS switch.
27 FW-1402 Probable Cause Indicates that the flash usage percentage has fallen below the low boundary. Flash increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
FW-1425 27 FW-1425 Message , [FW-1425], ,, INFO, , Switch status changed from to HEALTHY. Probable Cause Indicates that the switch status has changed to a healthy state. This occurred because a policy is no longer violated. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
27 FW-1428 FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the missing power supply.
FW-1431 27 FW-1431 Message , [FW-1431], ,, WARNING, , Switch status change contributing factor Fan: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when sensor value is not in the acceptable range or is faulty.
27 FW-1434 FW-1434 Message , [FW-1434], ,, WARNING, , Switch status change contributing factor Blade: blade failures. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of blade failures is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the faulty blade.
FW-1437 27 FW-1437 Message , [FW-1437], ,, WARNING, , Switch status change contributing factor faulty ports: . (Port(s) . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty ports is greater than or equal to the policy set by the switchStatusPolicySet command.
27 FW-1440 FW-1440 Message , [FW-1440], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “absent”. Recommended Action No action is required. Verify that the event was planned. Severity INFO FW-1441 Message , [FW-1441], ,, INFO, , state has changed to .
FW-1444 27 FW-1444 Message , [FW-1444], ,, WARNING, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “faulty”. Recommended Action Replace the FRU. Severity WARNING FW-1445 Message , [FW-1445], ,, INFO, , Four power supplies are now required for 2X redundancy, Switch Status Policy values changed.
27 FW-1500 FW-1500 Message , [FW-1500], ,, WARNING, , Mail overflow - Alerts being discarded. Probable Cause Indicates that mail alert overflow condition has occurred. Recommended Action Resolve or disable the mail alert using the fwMailCfg command. Severity WARNING FW-1501 Message , [FW-1501], ,, INFO, , Mail overflow cleared - alerts discarded.
Chapter HAM System Messages 28 HAM-1001 Message , [HAM-1001], , FFDC, CRITICAL, , Standby CP is not healthy, device status BAD, Severity = Probable Cause Indicates that a standby control processor (CP) device error is reported by the high-availability manager (HAM) Health Monitor, with a specific device and Log="YES” Class=”NONE" Severity level. The severity level can be “critical”, “major”, or “minor”.
28 HAM-1005 • • • • • • • • • • • • • • • • • • • Recommended Action Severity Unknown Fastboot Giveup Master:SYSM CP Faulty:SYSM FirmwareDownload ConfigDownload:MS ChangeWWN:EM Reboot:WebTool Fastboot:WebTool Software Fault:Software Watchdog Software Fault:Kernel Panic Software Fault:ASSERT Reboot:SNMP Fastboot:SNMP Reboot Chassis Config Reboot:API Reboot:HAM EMFault:EM Check the error log on both CPs for additional messages that might indicate the reason for the reboot.
HAM-1006 Recommended Action Severity 28 The standby CP will take over and reset the active CP.The system will be non-redundant as the standby becomes the active CP.
28 238 HAM-1006 Fabric OS Message Reference 53-1000437-01
Chapter HAMK System Messages 29 HAMK-1001 Message , [HAMK-1001], , FFDC, CRITICAL, , Warm recovery failed. Probable Cause The switch failed in the warm recovery. Recommended Action This message triggers a switch reboot automatically and attempts a cold recovery. RUn supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
29 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the standby CP has been rebooted. Note that in certain circumstances a CP may experience a double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice.
Chapter HIL System Messages 30 HIL-1101 Message , [HIL-1101], ,, ERROR, , Slot faulted, () is above threshold. Probable Cause Indicates that the blade voltage is above the threshold. Recommended Action Replace the faulty blade or switch (for nonbladed switches).
30 HIL-1104 HIL-1104 Message , [HIL-1104], ,, ERROR, , Blower faulted, () is below threshold. Probable Cause Indicates that the fan voltage is below the threshold. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are seated properly.
HIL-1107 30 HIL-1107 Message , [HIL-1107], ,, ERROR, , Switch faulted, ()above threshold. Probable Cause Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and is not applicable to the Brocade 24000, or 48000.
30 HIL-1202 If the fan continues to generate this message, replace the fan field-replaceable unit (FRU). Severity WARNING HIL-1202 Message , [HIL-1202], ,, ERROR, , Blower faulted, speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold. Recommended Action Replace the fan field-replaceable unit (FRU).
HIL-1206 30 HIL-1206 Message , [HIL-1206], ,, ERROR, , Fan sensor , speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000, or 48000.
30 HIL-1301 HIL-1301 Message , [HIL-1301], ,, WARNING, , 1 blower failed or missing. Replace failed or missing blower assembly immediately. Probable Cause Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Action Replace the affected fan FRU immediately.
HIL-1305 Severity 30 ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fan(s) failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan FRUs immediately. Severity ERROR HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed.
30 HIL-1309 Recommended Action Severity Replace the faulty fan field-replaceable units (FRUs) immediately. ERROR HIL-1309 Message , [HIL-1309], ,, ERROR, , fan FRUs failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan field-replaceable unit (FRU)s immediately.
HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Action Install the missing fan FRU. Severity 30 WARNING HIL-1402 Message , [HIL-1402], ,, WARNING, , Two fan FRUs missing. Install fan FRUs immediately. Probable Cause Indicates that two fan field-replaceable units (FRUs) have been removed. Recommended Action Install the missing fan FRUs immediately.
30 HIL-1502 Recommended Action Severity Run the fanShow command to verify all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. WARNING HIL-1502 Message , [HIL-1502], , FFDC, CRITICAL, , Slot , high temperature ().
HIL-1505 Recommended Action Severity 30 No action is required. INFO HIL-1505 Message , [HIL-1505], ,, WARNING, , High temperature ( C) exceeds environmental specifications. Probable Cause Indicates that temperatures in the system have risen above the warning threshold. Recommended Action Run the fanShow command to verify all the fans are working properly.
30 HIL-1508 HIL-1508 Message , [HIL-1508], , FFDC, CRITICAL, , Fan faulty warning time expired. System preparing for shutdown. Probable Cause Indicates that temperatures in the system have remained above the critical threshold too long. Recommended Action In order to avoid causing damage to the switch, the system shuts down automatically. To help prevent future problems, make sure that all the fans are working properly.
HIL-1601 30 HIL-1601 Message , [HIL-1601], ,, ERROR, , Using backup temperature sensor. Service immediately. Probable Cause Indicates that temperature readings from the primary sensor are out of range. Recommended Action Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating fan field-replaceable units (FRUs). Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch.
30 254 HIL-1602 Fabric OS Message Reference 53-1000437-01
Chapter HLO System Messages 31 HLO-1001 Message , [HLO-1001], , FFDC, ERROR, , Incompatible Inactivity timeout from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch.
31 HLO-1003 The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action 256 The HLO message of the remote switch must be compatible with the value specified in the FSPF protocol. Refer to documentation of the other manufacturer's switch to change this value.
Chapter HMON System Messages 32 HMON-1001 Message , [HMON-1001], , FFDC, CRITICAL, , Probable Cause Indicates that there was a problem reading an essential file containing configuration information from the nonvolatile storage device. This could be the result of a missing file or a corrupt file system. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch.
32 258 HMON-1001 Fabric OS Message Reference 53-1000437-01
Chapter HTTP System Messages 33 HTTP-1001 Message , [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that the PID format was changed by the administrator. Recommended Action No action is required. For more information on PID, format refer to the Fabric OS Administrator’s Guide.
33 260 HTTP-1003 Fabric OS Message Reference 53-1000437-01
Chapter IBD System Messages 34 IBD-1001 Message , [FKLB-1001], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power off and power on the blade using the slotPowerOff and slotPowerOn commands.
34 262 IBD-1001 Fabric OS Message Reference 53-1000437-01
Chapter IBPD System Messages 35 IBPD-1001 Message , [IBPD-1001], ,, WARNING, , : initiator name length exceeds the character limit [] Probable Cause Indicates that the initiator name length exceeds the supported limit of characters. Recommended Action Change the initiator name, keeping the number of characters within the supported limit.
35 264 IBPD-1003 Fabric OS Message Reference 53-1000437-01
Chapter ICPD System Messages 36 ICPD-1001 Message , [ICPD-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Severity Reboot or power cycle the switch.
36 ICPD-1004 ICPD-1004 Message , [ICPD-1004], ,, WARNING, , iSNS Client service is detected on multiple switches in fabric. Probable Cause Indicates that iSNS Client service is enabled on multiple switches in fabric. Recommended Action Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer to the Fabric OS Command Reference for more information on this command.
ICPD-1008 36 ICPD-1008 Message , [ICPD-1008], ,, INFO, , iSCSI switch () is . Probable Cause Indicates that the iSCSI switch is reachable or unreachable. Recommended Action No action is required.
36 268 ICPD-1008 Fabric OS Message Reference 53-1000437-01
Chapter IPAD System Messages 37 IPAD-1000 Message , [IPAD-1000], ,, INFO,
37 270 IPAD-1001 Fabric OS Message Reference 53-1000437-01
Chapter IPS System Messages 38 IPS-1001 Message , [IPS-1001], ,, WARNING, , FCIP License Not Installed () Probable Cause Indicates that the FCIP license is not installed on the switch. Recommended Action Run the licenseShow command to check the installed licenses on the switch. Contact your switch supplier for a FCIP license. Run the licenseAdd command to add the license to your switch.
38 IPS-1005 Probable Cause Indicates that configured Port Mode is different from intended use. Recommended Action Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port mode to neutral before attempting to configure the port for a different mode or use.
Chapter ISCS System Messages 39 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates that specified port has crashed. Recommended Action No action is required; the port will restart automatically.
39 274 ISCS-1000 Fabric OS Message Reference 53-1000437-01
Chapter ISNS System Messages 40 ISNS-1001 Message , [ISNS-1001], ,, INFO, , Configuration peering with external iSNS server slot/port /ge (current /ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended Action No action is required.
40 ISNS-1004 ISNS-1004 Message , [ISNS-1004], ,, WARNING, , Timeout refreshing iSNS database with iSNS server slot/port /ge Reg-Period . Probable Cause Indicates that the internet storage name service (iSNS) client failed to receive a successful response for a DevAttrQry within the specified Registration-Period.
ISNS-1008 40 ISNS-1008 Message , [ISNS-1008], ,, INFO, , Peering with external iSNS server not started because configuration unchanged. Probable Cause Indicates that peering with the external iSNS server was already started with the same configuration. Recommended Action No action is required. You may change the configuration and retry the peering with the external iSNS server.
40 ISNS-1013 Severity INFO ISNS-1013 Message , [ISNS-1013], ,, WARNING, , iSNS server connection failure. Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Action Verify the connection of the iSNS server to the slot/port. Use the isnscCfg command to display or correct the server IP address.
Chapter KSWD System Messages 41 KSWD-1003 Message , [KSWD-1003], , FFDC, WARNING, , kSWD: . Probable Cause Indicates a warning state within the system. A critical application error was reported in the watchdog subsystem. Refer to the string at the end of the error message for specific information. The switch will reboot (on single-CP switches) or failover (on dual-CP switches).
41 280 KSWD-1003 Fabric OS Message Reference 53-1000437-01
Chapter KTRC System Messages 42 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Cause Indicates that the dump memory size has exceeded the dump file size. Recommended Action No action is required. Severity WARNING KTRC-1002 Message , [KTRC-1002], ,, INFO, , Concurrent trace dumping. Probable Cause Indicates that the initial background dump has not completed.
42 KTRC-1005 Recommended Action Severity No action is required. ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that Trace was unable to initialize. Recommended Action No action is required.
Chapter LOG System Messages 43 LOG-1000 Message , [LOG-1000], ,, INFO, , Previous message repeated time(s) Probable Cause Indicates that the previous message repeated the specified number of times. Recommended Action No action is required. Severity INFO LOG-1001 Message , [LOG-1001], , FFDC, WARNING, , A log message was dropped Probable Cause Indicates that a log message was dropped.
43 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates that the persistent error log has been cleared. Recommended Action No action is required.
Chapter LSDB System Messages 44 LSDB-1001 Message , [LSDB-1001], ,, ERROR, , Link State ID out of range Probable Cause Indicates that the specified link state database ID is out of the acceptable range. The valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended Action No action is required.
44 LSDB-1004 Recommended Action Severity Run the switchDisable and switchEnable commands. A new local link state record is generated during the switch enable. CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain Probable Cause Indicates that there is no link state record for the specified local domain. Recommended Action No action is required.
Chapter MFIC System Messages 45 MFIC-1001 Message , [MFIC-1001], ,, ERROR, , failure at sysmod_scn registry rc= Probable Cause Indicates that the system is temporarily out of resources. Recommended Action No action is required; this message is often transitory. If the message persists, run a switch reboot or an haFailover (if applicable).
45 MFIC-1003 MFIC-1003 Message , [MFIC-1003], ,, WARNING, , Effective Insistent domain ID for the fabric changed from to Probable Cause Indicates that one or more switches joined the fabric with a different insistent domain ID (IDID) mode setting than the current effective IDID mode for the fabric. This message also occurs when the IDID for the fabric has been turned on or off. The possible values for state are "On" or "Off".
Chapter MPTH System Messages 46 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates that a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the tree. Recommended Action No action is required.
46 290 MPTH-1003 Fabric OS Message Reference 53-1000437-01
Chapter MQ System Messages 47 MQ-1004 Message Probable Cause , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Indicates that an unexpected message has been received in the specified message queue. The queue name is always fspf_q.
47 292 MQ-1004 Fabric OS Message Reference 53-1000437-01
Chapter MS System Messages 48 MS-1001 Message , [MS-1001], ,, WARNING, , MS Platform Segmented port=( ) Probable Cause Indicates that the management server (MS) has segmented from another switch domain at the specified port number due to errors or inconsistencies defined in the MS platform service. Recommended Action Reboot or power cycle the switch.
48 MS-1003 • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. Severity INFO MS-1003 Message Probable Cause , [MS-1003], ,, INFO, , MS detected Unstable Fabric().
MS-1005 Severity 48 INFO MS-1005 Message , [MS-1005], ,, ERROR, , MS Invalid CT Response from d= Probable Cause Indicates that the management server (MS) received an invalid common transport (CT) response from switch domain. MS expects either a CT accept IU or a reject IU; MS received neither response, which violates the Fibre Channel Generic Services (FS-GS) specification.
48 MS-1009 MS-1009 Message Probable Cause , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is . Device Port Tag is . . A Registered Link Incident Record (RLIR) has been generated for one of the actions clarified by the passed in. The following messages might be displayed: • • • • • Recommended Action Severity Exceeded bit error rate threshold Loss of signal or synchronization Not operational seq.
MS-1023 48 MS-1023 Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service Probable Cause Indicates that Management Server Topology Discovery Service is being enabled or disabled. Recommended Action No action is required.
48 298 MS-1024 Fabric OS Message Reference 53-1000437-01
Chapter NBFS System Messages 49 NBFS-1001 Message Probable Cause , [NBFS-1001], ,, INFO, , Duplicate E_Port SCN from port in state () Indicates that a duplicate E_Port State Change Number was reported.
49 NBFS-1003 Severity ERROR NBFS-1003 Message Probable Cause , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set in state , input , port Indicates that the database transmit set flag was not set for the specified input state on the specified port.
Chapter NS System Messages 50 NS-1001 Message , [NS-1001], ,, WARNING, , The response for request 0x from remote switch 0x is larger than the max frame size the remote switch can support! Probable Cause Indicates that the response payload exceeds the maximum frame size that the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, or v3.
50 NS-1004 Recommended Action To avoid disruption of traffic in the event of an unplanned failover, schedule a firmwareDownload so that the active and standby CPs have the same firmware version. Reduce the local device count to follow the capability of the lowest version of firmware.
Chapter PDM System Messages 51 PDM-1001 Message , [PDM-1001], ,, WARNING, , Failed to parse the pdm config. Probable Cause Indicates that the parity data manager (PDM) process could not parse the configuration file. This might be caused by a missing configuration file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware.
51 PDM-1004 PDM-1004 Message , [PDM-1004], ,, WARNING, , PDM memory shortage. Probable Cause Indicates that the parity data manager (PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
PDM-1008 Recommended Action Severity 51 Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1008 Message , [PDM-1008], ,, WARNING, , Failed to get the number of U_Ports. Probable Cause Indicates that the parity data manager (PDM) system call to getCfg failed.
51 PDM-1011 PDM-1011 Message , [PDM-1011], ,, WARNING, , File read failed: Probable Cause Indicates that the parity data manager (PDM) process could not read data from the specified file. Recommended Action Run the firmwareDownload command to reinstall the firmware. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
PDM-1017 51 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1017 Message , [PDM-1017], , FFDC, CRITICAL, , System (): . Probable Cause Indicates that the specified system call failed. Recommended Action Run the firmwareDownload command to reinstall the firmware.
51 PDM-1022 Probable Cause Indicates that a system call failed. Recommended Action Run the firmwareDownload command to reinstall the firmware. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1022 Message , [PDM-1022], ,, WARNING, , The switch is configured only with IPv6.
PDM-1024 Fabric OS Message Reference 53-1000437-01 51 309
51 310 PDM-1024 Fabric OS Message Reference 53-1000437-01
Chapter PDTR System Messages 52 PDTR-1001 Message , [PDTR-1001], ,, INFO, , < informational message > Probable Cause Indicates that information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved.
52 312 PDTR-1002 Fabric OS Message Reference 53-1000437-01
Chapter PLAT System Messages 53 PLAT-1000 Message , [PLAT-1000], , FFDC, CRITICAL, , Probable Cause Indicates that nonrecoverable PCI errors have been detected. Recommended Action The system will be faulted and might automatically reboot. If the system does not reboot, then try issuing the reboot command from a command-line prompt.
53 314 PLAT-1001 Fabric OS Message Reference 53-1000437-01
Chapter PORT System Messages 54 PORT-1003 Message , [PORT-1003], ,, WARNING, , Port Faulted because of many Link Failures Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple failures that exceed an internally set threshold on the port. This problem is typically related to hardware.
54 PORT-1005 PORT-1005 Message , [PORT-1005], ,, WARNING, , Slot port does not support configured L_port. Issue portCfgLport to clear configuration. Probable Cause Indicates that the specified port is configured to be an L_port, but that port does not support L_port. If an L_port is connected, then the port will be disabled because it does not support L_port.
Chapter PS System Messages 55 PS-1000 Message , [PS-1000], , FFDC, CRITICAL, , Failed to initialize Advanced Performance Monitoring. Probable Cause Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The Performance Monitor has failed to initialize. Recommended Action The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to reinitiate the firmware.
55 PS-1003 PS-1003 Message , [PS-1003], ,, WARNING, , Failed to set end-to-end monitoring mask on ISL ports. Probable Cause Indicates that the restoring configuration has attempted to set the end-to-end monitoring mask on at least one ISL port. Recommended Action No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled. ISL monitoring can only be disabled through the Fabric Access API.
Chapter PSWP System Messages 56 PSWP-1001 Message , [PSWP-1001], ,, INFO, , Areas for port and port are swapped. New area for port is and port is .
56 320 PSWP-1003 Fabric OS Message Reference 53-1000437-01
Chapter RAS System Messages 57 RAS-1001 Message , [RAS-1001], ,, INFO, , First failure data capture (FFDC) event occurred. Probable Cause Indicates that a failure happened and the failure data was captured. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
57 RAS-1004 RAS-1004 Message , [RAS-1004], , FFDC, WARNING, , Software 'verify' error detected. Probable Cause Indicates a internal software error. Recommended Action Run the supportSave command and contact your switch service provider. Severity WARNING RAS-1005 Message , [RAS-1005], , FFDC, WARNING, , Software 'assert' error detected. Probable Cause Indicates a internal software error.
Chapter RCS System Messages 58 RCS-1001 Message , [RCS-1001], ,, INFO, , RCS has been disabled. Some switches in the fabric do not support this feature. Probable Cause Indicates that the RCS feature has been disabled on the local switch because not all switches in the fabric support RCS or the switch is in nonnative mode. Recommended Action Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.
58 RCS-1004 RCS-1004 Message , [RCS-1004], ,, ERROR, , Application() not registered.() Probable Cause Indicates that a specified application did not register with RCS. Recommended Action Run the haShow command to view the HA state. Run the haDisable and the haEnable commands. Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.1 and greater, v4.1 and greater.
RCS-1006 58 RCS-1006 Message Probable Cause , [RCS-1006], ,, INFO, , State , Application AD, RCS CM. Domain returned 0x. Indicates that a remote domain rejected an RCS phase initiated by an application on the local switch. If the reject phase is ACA, the remote domain might be busy and could not process the new request.
58 326 RCS-1008 Fabric OS Message Reference 53-1000437-01
Chapter RPCD System Messages 59 RPCD-1001 Message , [RPCD-1001], ,, WARNING, , Authentication Error: client \"\" has bad credentials: Probable Cause Indicates that an authentication error was reported. The specified client IP address has faulty credentials. Recommended Action Enter the correct user name and password from the Fabric Access API host.
59 RPCD-1004 RPCD-1004 Message , [RPCD-1004], ,, WARNING, , Invalid certificate file. Secure RPCd is disabled. Probable Cause Indicates that the SSL certificate file has been corrupted. Recommended Action To enable RPCD in Secure mode, install a valid SSL certificate the switch. Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing private key file. Secure RPCd is disabled.
Chapter RTWR System Messages 60 RTWR-1001 Message , [RTWR-1001], ,, ERROR, , RTWR 0x, 0x, 0x, 0x, 0x Probable Cause Indicates that an error occurred in the RTWR. The message provides the name of the routine having the error, and more specific error information. The values in details 1 through 5 might provide more information. Recommended Action No action is required.
60 RTWR-1003 RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry to domain , iu_data Probable Cause Indicates how many times RTWR failed to get a response and retried. Recommended Action Run the dom command to verify that the specified domain ID is reachable.
Chapter SAS System Messages 61 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid=. Probable Cause The Hardware is not responding to the command request; possibly because it is busy. Recommended Action Retry the command.
61 332 SAS-1001 Fabric OS Message Reference 53-1000437-01
Chapter SCN System Messages 62 SCN-1001 Message Probable Cause , [SCN-1001], , FFDC, CRITICAL, , SCN queue overflow for process Indicates that an attempt to write a state change notification (SCN) message to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or if the system is busy.
62 334 SCN-1001 Fabric OS Message Reference 53-1000437-01
Chapter SEC System Messages 63 SEC-1001 Message , [SEC-1001], ,, ERROR, , RCS process fails: Probable Cause Indicates that the reliable commit service (RCS) process fails to complete. RCS is a mechanism for transferring data from one switch to other switches within the fabric. RCS ensures that either all or none of the switches commit to the database.
63 SEC-1003 SEC-1003 Message , [SEC-1003], ,, WARNING, , Fail to download security data to domain after retries Probable Cause Indicates that the specified domain failed to download security data after the specified number of attempts, and that the failed switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries.
SEC-1007 63 SEC-1007 Message , [SEC-1007], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection. Probable Cause Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the API connection.
63 SEC-1016 SEC-1016 Message , [SEC-1016], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish SSH connection. Probable Cause Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the SSH connection.
SEC-1025 63 SEC-1025 Message , [SEC-1025], ,, ERROR, , Invalid IP address () detected. Probable Cause Indicates that a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configurations server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
63 SEC-1029 SEC-1029 Message , [SEC-1029], ,, ERROR, , Invalid character in . Probable Cause Indicates that a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configurations server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
SEC-1032 63 SEC-1032 Message , [SEC-1032], ,, ERROR, , Empty FCS list is not allowed. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
63 SEC-1035 SEC-1035 Message , [SEC-1035], ,, ERROR, , Invalid device WWN . Probable Cause Indicates that the specified world-wide name (WWN) is invalid. Recommended Action Enter the correct WWN value. Severity ERROR SEC-1036 Message , [SEC-1036], ,, ERROR, , Device name is invalid due to a missing colon.
SEC-1040 63 SEC-1040 Message , [SEC-1040], ,, ERROR, , Invalid portlist (). Cannot combine * with port member in the same portlist. Probable Cause Indicates that the port list contains the wildcard asterisk (*) character. You cannot use the asterisk in a port list. Recommended Action Enter the port list values without any wildcards.
63 SEC-1043 SEC-1043 Message , [SEC-1043], ,, ERROR, , Invalid port range - . Probable Cause Indicates that the specified port is not within the minimum and maximum range. Recommended Action Use valid syntax when entering port ranges. Severity ERROR SEC-1044 Message , [SEC-1044], ,, ERROR, , Duplicate member in ().
SEC-1046 63 SEC-1046 Message , [SEC-1046], ,, ERROR, , Empty list. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
63 SEC-1051 SEC-1051 Message , [SEC-1051], ,, ERROR, , Missing brace for port list . Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1054 63 SEC-1054 Message , [SEC-1054], ,, ERROR, , Invalid FCS list length Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
63 SEC-1057 SEC-1057 Message , [SEC-1057], ,, ERROR, , No change. Both positions are the same. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1063 63 SEC-1063 Message , [SEC-1063], ,, ERROR, , Failed to reset statistics. Probable Cause Indicates that either the type or domains specified are invalid. Recommended Action Enter valid input. Severity ERROR SEC-1064 Message , [SEC-1064], ,, ERROR, , Failed to sign message.
63 SEC-1071 SEC-1071 Message , [SEC-1071], ,, ERROR, , No new security policy data to apply. Probable Cause Indicates that no changes in the defined security policy database need to be activated at this time. Recommended Action Verify that the security event was planned. First change some policy definitions, then run the secPolicyActivate command to activate the policies.
SEC-1074 63 SEC-1074 Message , [SEC-1074], ,, ERROR, , Cannot execute the command on this switch. Please check the secure mode and FCS status. Probable Cause Indicates that a security command was run on a switch that is not allowed to run it either because it is in non-secure mode or because it does not have required fabric configurations server (FCS) privilege.
63 SEC-1077 SEC-1077 Message , [SEC-1077], ,, ERROR, , Failed to activate new policy set on all switches. Probable Cause Indicates that the policy could not be activated. Possible reasons that the policy could not be activate include not enough memory or a busy switch. Recommended Action Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Retry the command when all switches are ready.
SEC-1080 63 SEC-1080 Message , [SEC-1080], ,, ERROR, , Operation denied. Please, use secModeEnable command. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
63 SEC-1083 SEC-1083 Message , [SEC-1083], ,, ERROR, , Name already exists. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1086 63 SEC-1086 Message , [SEC-1086], ,, ERROR, , The security database is too large to fit in flash. Probable Cause Indicates that the security database has more data than the flash can accommodate. Recommended Action Reduce the number of entries in some policies to decrease the security database size.
63 SEC-1089 SEC-1089 Message , [SEC-1089], ,, ERROR, , Policy name was not found. Probable Cause Indicates that the security policy name in the secPolicyAdd command does not exist. Recommended Action Create the appropriate security policy first, then use its name in the secPolicyAdd command to add new members. Severity ERROR SEC-1090 Message , [SEC-1090], ,, ERROR, , SCC list contains FCS member.
SEC-1092 63 SEC-1092 Message , [SEC-1092], ,, ERROR, , Name not found. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
63 SEC-1095 SEC-1095 Message , [SEC-1095], ,, ERROR, , Deleting FCS policy is not allowed. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1098 63 SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS list. Probable Cause Indicates that the specified policy could not be found. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
63 SEC-1101 SEC-1101 Message , [SEC-1101], ,, ERROR, , Failed to enable security on all switches. Please retry later. Probable Cause Indicates that the security enable failed on the fabric because one or more switches in the fabric are busy. Recommended Action Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in the ready state.
SEC-1105 63 SEC-1105 Message , [SEC-1105], ,, ERROR, , Fail to disable secure mode on all switches. Probable Cause Indicates that the switch failed to disable security in the fabric. This could happen if the switch cannot get the required resources to complete the command, and sending to a remote domain fails or the remote domain returns an error. Recommended Action Run the secFabricShow to verify that all switches in the fabric are in the ready state.
63 SEC-1108 SEC-1108 Message , [SEC-1108], ,, ERROR, , Fail to reset stamp on all switches. Probable Cause Indicates that a version reset operation failed either because the switch could not get all the required resources to perform the operation or because it failed to send the message to all switches in the fabric. Recommended Action Verify that the security event was planned.
SEC-1112 63 SEC-1112 Message , [SEC-1112], ,, ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Indicates that either a security policy download is attempted with an active policy that does not have the fabric configurations server (FCS) policy as the first policy or the FCS policy is not same as the current FCS policy on the switch.
63 SEC-1117 SEC-1117 Message , [SEC-1117], ,, INFO, , Fail to set . Probable Cause Indicates that the switch failed to save the data received by the primary fabric configurations server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Action Run the secFabricShow command to verify that all switches in fabric are in the ready state.
SEC-1121 63 SEC-1121 Message , [SEC-1121], ,, ERROR, , Time is out of range when . Probable Cause Indicates that the time on the switch is not synchronized with the primary fabric configurations server (FCS), the data packet is corrupted, or a replay attack is launched on the switch. Recommended Action Verify that the security event was planned.
63 SEC-1126 Severity INFO SEC-1126 Message , [SEC-1126], ,, INFO, , Secure mode has been disabled. Probable Cause Indicates that a secure mode disable operation completed successfully. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1136 63 SEC-1136 Message , [SEC-1136], ,, ERROR, , Failed to verify signature . Probable Cause Indicates that the receiving switch fails to validate the security database sending from the primary fabric configurations server (FCS) switch.
63 SEC-1139 SEC-1139 Message , [SEC-1139], ,, ERROR, , The RSNMP_POLICY cannot exist without the WSNMP_POLICY. Probable Cause Indicates that the receiving switch fails to validate the security database sending from the primary fabric configurations server (FCS) switch.
SEC-1146 63 SEC-1146 Message , [SEC-1146], ,, INFO, , PID changed: . Probable Cause Indicates that the PID format of the switch was changed either to extended-edge PID or from extended-edge PID. If the device connection control (DCC) polices existed, all index/area ID values either increased or decreased by 16. The values wrap around after 128.
63 SEC-1155 SEC-1155 Message , [SEC-1155], ,, INFO, , PID change failed: . Probable Cause Indicates that either the defined or active policy was too large after modifying the index/area ID. The status values can be either defined, active, or both. A negative value means that a policy set was failed by the daemon. Recommended Action Reduce the size of the specified policy database.
SEC-1158 63 SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name . Probable Cause Indicates that the specified name is invalid. The name can be a policy name or a switch name. Recommended Action Enter a valid name. Severity INFO SEC-1159 Message , [SEC-1159], ,, INFO, , Non_Reachable domain .
63 SEC-1163 SEC-1163 Message , [SEC-1163], ,, ERROR, , System is already in secure mode. Lockdown option cannot be applied. Probable Cause Indicates that the lockdown option was attempted while the fabric is already in secure mode. Recommended Action Do not use the lockdown option with the secModeEnable command when switch is already in secure mode.
SEC-1166 63 SEC-1166 Message , [SEC-1166], ,, ERROR, , Non FCS tries to commit failover. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
63 SEC-1170 SEC-1170 Message , [SEC-1170], ,, INFO, , This command must be executed on the Primary FCS switch, the first reachable switch in the FCS list. Probable Cause Indicates that there has been a corruption during the distribution of the security database.
SEC-1173 63 SEC-1173 Message , [SEC-1173], ,, ERROR, , Lost contact with Primary FCS switch. Probable Cause Indicates that the switch has lost contact with the primary fabric configurations server (FCS) switch in the secure fabric. This could be due to the primary FCS being disabled. Recommended Action If the primary FCS was disabled intentionally, no action is required; if not, check the primary FCS.
63 SEC-1180 SEC-1180 Message , [SEC-1180], ,, INFO, , Added account with authorization. Probable Cause Indicates that the specified new account has been created. Recommended Action No action is required. Severity INFO SEC-1181 Message , [SEC-1181], ,, INFO, , Deleted account Probable Cause Indicates that the specified account has been deleted.
SEC-1184 63 SEC-1184 Message , [SEC-1184], ,, INFO, , RADIUS configuration change, action , server ID . Probable Cause Indicates that the specified action is applied to the specified remote authentication dial-in user service (RADIUS) server configuration. The possible values for actions are “ADD”, “REMOVE”, “CHANGE”, and “MOVE”. Recommended Action No action is required.
63 SEC-1187 SEC-1187 Message , [SEC-1187], ,, INFO, , Security violation: Unauthorized switch tries to join fabric. Probable Cause Indicates that a switch connection control (SCC) security violation was reported. The specified unauthorized switch attempts to join the fabric. Recommended Action Check the switch connection control policy (SCC) policy to verify the switches allowed in the fabric.
SEC-1190 63 SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates that an SNMP security violation was reported. The specified unauthorized host attempted to perform a read SNMP operation. Recommended Action Check the RSNMP policy to verify that hosts allowed access to the fabric through SNMP read operations are included in the RSNMP policy.
63 SEC-1193 SEC-1193 Message , [SEC-1193], ,, INFO, , Security violation: Login failure attempt via . IP Addr: Probable Cause Indicates that a specified login security violation was reported. The incorrect password was used while trying to log in through the specified connection method; the login failed. Recommended Action The error message lists the violating IP address.
SEC-1196 63 SEC-1196 Message , [SEC-1196], ,, WARNING, , Switch does not have all default account names. Probable Cause Indicates that the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Action Reset the default admin and user account names on the switch that reported the warning and retry enabling security.
63 SEC-1199 SEC-1199 Message , [SEC-1199], ,, INFO, , Security violation: Unauthorized access to serial port of switch . Probable Cause Indicates that a serial connection policy security violation was reported. An attempt was made to access the serial console on the specified switch instance when it is disabled. Recommended Action Check to see if an authorized access attempt is being made on the console.
SEC-1202 63 SEC-1202 Message , [SEC-1202], ,, INFO, , Security violation: Unauthorized access from MS device node name , device port name . Probable Cause Indicates that a management server (MS) security violation was reported. The unauthorized device specified in the message attempted to establish a connection. Recommended Action Check the MS server policy and verify that the connection is allowed.
63 SEC-1251 SEC-1251 Message , [SEC-1251], ,, ERROR, , Policy to binary conversion error: . Probable Cause Indicates that the security database conversion failed because of invalid values. The reason is specified in the text message variable and faulty value is printed in value variable. Recommended Action Retry the failed security command.
SEC-1301 63 SEC-1301 Message , [SEC-1301], ,, INFO, , This switch is in interop mode. Security is not supported. Probable Cause Indicates that the switch is interop-mode enabled. Recommended Action Disable interop-mode using the interopMode command before enabling the Secure Fabric OS feature.
63 SEC-1304 SEC-1304 Message , [SEC-1304], ,, INFO, , This switch has no security license. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1307 63 SEC-1307 Message , [SEC-1307], ,, INFO, , Got response from RADIUS server . Probable Cause Indicates that after some servers timed out, the specified remote authentication dial-in user service (RADIUS) server responded to a switch request. Recommended Action If the message appears frequently, move the responding server to the top of the RADIUS server configuration list using the aaaConfig command.
63 SEC-1311 Severity INFO SEC-1311 Message , [SEC-1311], ,, ERROR, , Security mode cannot be enabled because one or more of the password policies is not set to default value. Probable Cause Indicates that the security enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Recommended Action Verify that the security event was planned.
SEC-1314 63 SEC-1314 Message , [SEC-1314], ,, ERROR, , Reading IP address from EM failed. Probable Cause Indicates that the call to the EM module to retrieve the IP address failed. Recommended Action Please reboot the system to fix this error. If the problem persists contact your switch service provider.
63 SEC-1317 SEC-1317 Message , [SEC-1317], ,, INFO, , Inconsistent fabric, rejecting transaction Probable Cause Indicates that either this domain is performing an FDD merge or matched domains are not the same as what the CM sees. Recommended Action If a policy conflict exists, resolve it, then wait for the fabric to become stable. Retry the distribution.
SEC-1321 63 SEC-1321 Message , [SEC-1321], ,, ERROR, , Failed secure mode enable command. Reason: . Probable Cause Indicates that the security enable failed on the fabric because switch has conflicting configuration such as fabric wide consistency configuration or AD configuration. Recommended Action Verify that the security event was planned.
63 SEC-1324 SEC-1324 Message , [SEC-1324], ,, INFO, , Fabric transaction failure. RCS error: Probable Cause Indicates that the reliable commit service (RCS) transaction failed with specified reason code. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1327 63 SEC-1327 Message , [SEC-1327], ,, WARNING, , Strict policy is conflicting with domain Probable Cause Strict policy is conflicting. Recommended Action None, the domain is denied by disallowing all its E-ports connected to the fabric. If the domain should be allowed to merge with the fabric, then resolve the issue by making the conflicting policies same.
63 SEC-1331 Recommended Action Severity Verify that the distribution is initiated by the primary FCS switch. Use the secPolicyShow command to verify and correct the configuration if necessary. ERROR SEC-1331 Message , [SEC-1331], ,, ERROR, , Attempt to enable secure mode failed. Reason: .
Chapter SNMP System Messages 64 SNMP-1001 Message , [SNMP-1001], ,, ERROR, , SNMP service is not available . Probable Cause Indicates that the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Action Verify that the IP address for the Ethernet and Fibre Channel interface is set correctly.
64 SNMP-1004 SNMP-1004 Message , [SNMP-1004], , FFDC, ERROR, , Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Action Change the SNMP configuration back to the default.
Chapter SS System Messages 65 SS-1000 Message , [SS-1000], ,, INFO, , supportSave has ftp'ed support information to the host with IP address . Probable Cause Indicates that the supportSave command was used to transfer support information to a remote FTP location. Recommended Action No action is required.
65 398 SS-1001 Fabric OS Message Reference 53-1000437-01
Chapter SULB System Messages 66 SULB-1001 Message , [SULB-1001], , AUDIT, WARNING, , Firmwaredownload command has started. Probable Cause Indicates that the firmwareDownload command has been entered. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption.
66 SULB-1005 SULB-1005 Message , [SULB-1005], ,, INFO, , Current Active CP is preparing to failover. Probable Cause Indicates that the active CP is about to reboot. The standby CP is taking over as the active CP. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Severity Run the firmwareDownloadStatus command for more information.
SULB-1009 66 SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], AUDIT, INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates that the firmwareDownload command failed. The additional status code and error code provide debugging information. Table lists firmwareDownload status messages and status codes. Some of them will not show up in this RASLOG message.
66 SULB-1009 TABLE 6 402 Status Messages and Status Codes Status Message Status Code "Standby CP booted up." 0x65 "Active and Standby CP failed to gain HA synchronization within 10 minutes." 0x66 "Standby rebooted successfully." 0x67 "Standby failed to reboot." 0x68 “firmwareCommit has started to restore the secondary partition.” 0x69 "Local CP is restoring its secondary partition." 0x6a “Unable to restore the secondary partition.
SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code “firmwareCommit has started on the local CP. Please use firmwareDownloadStatus and firmwareShow to see the firmware status.” 0x87 “firmwareCommit has started on the remote CP. Please use firmwareDownloadStatus and firmwareShow to see the firmware status.” 0x88 “Please use firmwareDownloadStatus and firmwareShow to see the firmware status.” 0x89 “firmwareDownload command has completed successfully.
66 SULB-1009 Table 7 lists additional firmwareDownload error messages and error codes. They provide more details on why firmwareDownload failed. TABLE 7 404 Error Messages and Error Codes Error Message Error Code "Image is up-to-date. No need to download the same version of firmware." 0xF “Upgrade is inconsistent. Run the bootEnv (root) command to correct the inconsistency before proceeding.” 0x10 “OSRootPartition is inconsistent.
SULB-1009 TABLE 7 66 Error Messages and Error Codes Error Message Error Code "Failed to install RPM package." 0x2b "Cannot downgrade directly to this version. Downgrade to an intermediate version first and then download the desired version." 0x2c “Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding.” 0x2d "Invalid RPM package. Please reload firmware packages on the file server.
66 SULB-1009 Table 8 lists the firmwareDownload state names and state values. They indicate where in the firmwareDownload process the error occurred.
SULB-1010 66 SULB-1010 Message , [SULB-1010], , AUDIT, INFO, , Firmwarecommit failed (status=0x). Probable Cause Indicates that the firmwareCommit failed. The error code provides debugging information. See Table 7for more information. Recommended Action If the failure is caused by an inconsistent filesystem, contact your switch service provider.
66 SULB-1020 Probable Cause The error may be caused by a blade initialization issue after the new firmware is downloaded and the blade is rebooted. The error may also be caused by an internal Ethernet issue or by a persistent storage failure. Recommended Action Run the slotShow command. If the blade is in FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload.
SULB-1023 Severity 66 WARNING SULB-1023 Message , [SULB-1023], AUDIT, WARNING, , The blade in slot has rebooted during firmwaredownload. Probable Cause The error may be caused by an unexpected disruption of the firmwareDownload command, for example, by powering off and on of the indicated BP blade in the middle of a firmwareDownload. The error may also be caused by persistent storage hardware failure or by a software error.
66 SULB-1026 SULB-1026 Message , [SULB-1026], , AUDIT, WARNING, , Firmware commit operation started on the blade in slot . Probable Cause firmwareCommit has started on the specified blade. The operation may be a normal part of firmwareDownload, or it may have started to repair the secondary partition of the blade if the secondary partition is corrupted. Recommended Action No action is required.
SULB-1034 Severity 66 WARNING SULB-1034 Message , [SULB-1034], , AUDIT, ERROR, , Firmwaredownload timed out. Probable Cause The error may be caused by a switch initialization issue after the internal image is relocated. It may also be caused by an internal Ethernet issue or by persistent storage failure. Recommended Action Reboot the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus to monitor the progress.
66 SULB-1037 Probable Cause Many reasons can cause HCL to fail, such as domain not confirmed Recommended Action Run the reBoot command to reboot the switch manually.
Chapter SWCH System Messages 67 SWCH-1001 Message , [SWCH-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates that the switch is enabled before it is ready. Recommended Action If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
67 SWCH-1004 SWCH-1004 Message , [SWCH-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = . Probable Cause Indicates that a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command.
SWCH-1007 67 SWCH-1007 Message , [SWCH-1007], ,, WARNING, , Switch port disabled due to \"\". Probable Cause Indicates that the switch port is disabled due to the reason displayed in the message. Recommended Action Based on the disable reason displayed, proper corrective action may to be required to restore the port.
67 416 SWCH-1008 Fabric OS Message Reference 53-1000437-01
Chapter SYSC System Messages 68 SYSC-1001 Message , [SYSC-1001], , FFDC, CRITICAL, , Failed to run :. Probable Cause Indicates that during the boot sequence, one of the programs would not run on the system. Recommended Action If the message is reported during a reboot after new firmware has been loaded, try reloading the firmware using the firmwareDownload command.
68 SYSC-1003 SYSC-1003 Message Probable Cause , [SYSC-1003], , FFDC, CRITICAL, , Chassis config option
Chapter SYSM System Messages 69 SYSM-1001 Message , [SYSM-1001], , FFDC, CRITICAL, , No memory. Probable Cause Indicates that the switch has run out of system memory. Recommended Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
69 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates that there was a failure to read configuration data from the WWN card. Recommended Action Verify that the world-wide name (WWN) card is present and operational and that the affected control processor (CP) is properly seated in its slot.
Chapter TRCE System Messages 70 TRCE-1001 Message Probable Cause , [TRCE-1001], ,, WARNING, , Trace dump available< optional slot indicating on which slot the dump occurs >! (reason: ) Indicates that trace dump files have been generated on the switch or the indicated slot.
70 TRCE-1003 TRCE-1003 Message , [TRCE-1003], ,, ERROR, , Trace dump< optional slot indicating on which slot the dump occurs > was not transferred due to FTP error. Probable Cause Indicates that a trace dump has been created on the switch or the indicated slot but is not automatically transferred from the switch due to an FTP error, such as a wrong FTP address, FTP site down, or network down.
TRCE-1006 70 TRCE-1006 Message , [TRCE-1006], ,, INFO, , FTP Connectivity Test succeeded to FTP site ' '. Probable Cause Indicates that a connectivity test to the FTP host has succeeded. This feature is enabled by the supportFtp -t command. Recommended Action No action is required. Severity INFO TRCE-1007 Message , [TRCE-1007], ,, ERROR, , Notification of this CP has failed.
70 TRCE-1009 TRCE-1009 Message , [TRCE-1009], ,, ERROR, , Unable to alert active CP that a dump has occurred. Probable Cause Indicates that the standby CP is unable to communicate trace information to active CP. This message is only applicable to the Brocade 24000 and 48000. Recommended Action Run the haShow command to verify that the current CP is standby and the active CP is active.
TRCE-1012 70 TRCE-1012 Message , [TRCE-1012], ,, WARNING, , The system was unable to retrieve trace information from slot . Probable Cause Indicates that communication between the main system and the indicated slot is unavailable. Recommended Action Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run the supportSave command and contact your switch service provider.
70 426 TRCE-1012 Fabric OS Message Reference 53-1000437-01
Chapter TRCK System Messages 71 TRCK-1001 Message , [TRCK-1001], ,, INFO, , Successful login by user . Probable Cause Indicates that the track change feature recorded a successful login. Recommended Action No action is required. Severity INFO TRCK-1002 Message , [TRCK-1002], ,, INFO, , Unsuccessful login by user . Probable Cause Indicates that the track change feature recorded a failed login.
71 TRCK-1004 TRCK-1004 Message , [TRCK-1004], ,, INFO, , Config file change from task: Probable Cause Indicates that the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not generated for a configUpload. All configuration changes occur through the PDM server, so the PDMIPC is the only task possible.
Chapter TS System Messages 72 TS-1001 Message Probable Cause , [TS-1001], ,, WARNING, , NTP Query failed: Indicates that a network time protocol (NTP) query to the configured external clock server failed. Local clock time on the principal or primary fabric configuration server (FCS) switch is used for fabric synchronization. This might be logged during temporary operational issues such as IP network connection issues to the external clock server.
72 TS-1006 TS-1006 Message Probable Cause , [TS-1006], ,, INFO, , Indicates that a time service event is occurring or has failed. The message might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits.
TS-1008 72 TS-1008 Message , [TS-1008], ,, WARNING, , Clock Server used instead of . Probable Cause Indicates that there is a change in the source of fabric time synchronization distributed from the principal or primary fabric configuration server (FCS) switch. Another clock server in the list of clock servers configured is being used.
72 432 TS-1008 Fabric OS Message Reference 53-1000437-01
Chapter UCST System Messages 73 UCST-1003 Message , [UCST-1003], ,, INFO, , Duplicate Path to Domain , Output Port = , PDB pointer = 0x Probable Cause Indicates that duplicate paths were reported to the specified domain from the specified output port. The path database (PDB) pointer is the address of the path database and provides debugging information. Recommended Action No action is required.
73 434 UCST-1020 Fabric OS Message Reference 53-1000437-01
Chapter UPTH System Messages 74 UPTH-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates that the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended Action No action is required. This will end the current SPF computation.
74 436 UPTH-1001 Fabric OS Message Reference 53-1000437-01
Chapter WEBD System Messages 75 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured to be enabled but could not be started. Probable Cause Indicates that the SSL certificate file is either invalid or absent. Recommended Action Run the configure command to disable HTTPS. Install a valid key file and enable HTTPS again. For more information on the configure command, refer to the Fabric OS Command Reference.
75 WEBD-1004 WEBD-1004 Message , [WEBD-1004], ,, INFO, , HTTP server will be restarted due to configuration change Probable Cause Indicates that the HTTP server configuration has changed. Recommended Action No action is required.
WEBD-1008 75 WEBD-1008 Message , [WEBD-1008], , FFDC, WARNING, , HTTP server cannot be started Probable Cause Indicates a rare error condition, where the built-in recovery process has failed to restore http services. The problem often results from invalid configuration of ssl certs., but there can be more than one reason for such failure. Recommended Action Run the configure command and disable/enable http or https.
75 440 WEBD-1008 Fabric OS Message Reference 53-1000437-01
Chapter ZOLB System Messages 76 ZOLB-1001 Message , [ZOLB-1001], ,, ERROR, , ZONELIB Probable Cause Indicates that there was an internal timeout on the inter process communication (IPC) between the name server (NS) and the zoning modules. This usually indicates that the system was busy. Recommended Action This message generates core dump files of the related modules (zoned, nsd, rcsd).
76 442 ZOLB-1001 Fabric OS Message Reference 53-1000437-01
Chapter ZONE System Messages 77 ZONE-1002 Message , [ZONE-1002], ,, WARNING, , WWN zoneTypeCheck or zoneGroupCheck warning() at port() Probable Cause Indicates that a zone filter or zone group check failure occurred. The frame filter logic reported a failure when creating or adding zone groups during port login (PLOGI) trap processing.
77 ZONE-1004 ZONE-1004 Message , [ZONE-1004], ,, INFO, , port enforcement changed to Session Based HARD Zoning. Probable Cause Indicates that the zoning enforcement changed to session-based hard zoning. When a device is zoned using both world-wide name (WWN) in one zone and in another, this will cause that port to go session based hard zoning. In session-based zoning, the zone enforcement is checked by the software.
ZONE-1006 77 ZONE-1006 Message , [ZONE-1006], ,, WARNING, , WARNING WWN() in HARD PORT zone . Probable Cause Indicates that one or more devices are zoned as world-wide name (WWN) devices and also zoned as devices. The device(s) are used to specify zone members over separate zones.
77 ZONE-1010 ZONE-1010 Message , [ZONE-1010], ,, WARNING, , WARNING Duplicate entries in zone() specification. Probable Cause Indicates that there are duplicate entries in a zone object. A zone object member is specified twice in a given zone object. This message occurs only when enabling a zone configuration. Recommended Action Check the members of the zone and delete the duplicate member.
ZONE-1014 77 ZONE-1014 Message , [ZONE-1014], ,, ERROR, , Missing required license - . Probable Cause Indicates that the required zoning license is missing. Recommended Action Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a Zoning license if you do not have one.
77 ZONE-1018 ZONE-1018 Message Probable Cause , [ZONE-1018], ,, ERROR, , Incorrect zoning enforcement type() at port(). Indicates that an incorrect zoning enforcement type was reported on the specified port. This is a software error. A QuickLoop zone type (value = 4) or an uninitialized type (value = 0) are invalid.
ZONE-1022 77 ZONE-1022 Message , [ZONE-1022], ,, INFO, , The effective configuration has changed to . Probable Cause Indicates that the effective zone configuration has changed to the name displayed. Recommended Action Verify that this zone configuration change was done on purpose. If the new effective zone configuration is correct, no action is necessary.
77 ZONE-1026 ZONE-1026 Message , [ZONE-1026], ,, INFO, , port Out of CAM entries. Probable Cause Indicates that the total number of S_ID entries while creating or adding a zone group exceeds the limit. Recommended Action If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that port.
ZONE-1028 77 ZONE-1028 Message , [ZONE-1028], ,, WARNING, , Commit zone DB larger than supported - greater than . Probable Cause Indicates that the zone database size is greater than the limit allowed by the fabric. The limit of the zone database size depends on the lowest level switch in the fabric. Older switches have less memory and force a smaller zone database for the entire fabric.
77 ZONE-1031 ZONE-1031 Message , [ZONE-1031], ,, ERROR, , Switch is in interop mode. (switch, port) members not supported. Probable Cause The switch is set to interop mode using the interopMode command. Interop mode does not allow members in the active zone database. Recommended Action Remove all members from the zone database, or convert them to world-wide name (WWN) zoning.
ZONE-1034 77 ZONE-1034 Message , [ZONE-1034], ,, WARNING, , Zoning file doesn't exist or Corrupted Zoning files detected before reboot, currently the file is saved at Probable Cause Indicates that the zone database is corrupt or zone database is not found. Recommended Action Use the firmwareDownload command to reinstall the firmware.
77 ZONE-1037 ZONE-1037 Message , [ZONE-1037], ,, ERROR, , Unable to examine : error message . Probable Cause Indicates that the Fabric OS cannot examine the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation.
ZONE-1040 77 ZONE-1040 Message , [ZONE-1040], ,, INFO, , Merged zone database exceeds limit. Probable Cause Indicates that the Fabric OS cannot read the merged zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation.
77 ZONE-1044 ZONE-1044 Message , [ZONE-1044], ,, INFO, , The Default Zone access mode is set to All Access. Probable Cause Indicates that the Default Zone access mode is set to All Access. Recommended Action Verify that this Default Zone access mode change was done intentionally. Severity INFO ZONE-1045 Message , [ZONE-1045], ,, INFO, , The Default Zone access mode is already set to No Access.
Chapter AUDIT AUTH System Messages 78 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type is “authentication type”, “DH group type”, “Hash type”, or “policy type”. Recommended Action No action is required.
78 AUTH-3004 AUTH-3004 Message AUDIT, , [AUTH-3004], INFO, SECURITY, , , , Event: , Status: failed, Info: Neighboring switch has a conflicting authentication policy; Port disabled. Probable Cause The specified E_Port was disabled because the neighboring switch rejected the authentication negotiation, and the local switch has a strict switch authentication policy.
AUTH-3007 78 AUTH-3007 Message Probable Cause AUDIT, , [AUTH-3007], INFO, SECURITY, , , , Event: , Status: failed, Info: Port disabled due to receiving an authentication reject with code '' and explanation ''. Indicates that the specified port was disabled due to receiving an authentication reject response from the connected switch/device.
78 460 AUTH-3008 Fabric OS Message Reference 53-1000437-01
Chapter AUDIT CONF System Messages 79 CONF-1000 Message AUDIT, , [CONF-1000], INFO, CFG, , , , configDownload completed successfully. . Probable Cause The configDownload process was initiated and completed successfully. The message string describes the class of configuration parameters that were downloaded. If admin domain (AD) is enabled, the AD number is specified in the description.
79 462 CONF-1022 Fabric OS Message Reference 53-1000437-01
Chapter AUDIT HTTP System Messages 80 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has been changed. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
80 464 HTTP-1003 Fabric OS Message Reference 53-1000437-01
Chapter AUDIT SEC System Messages 81 SEC-3001 Message AUDIT, , [SEC-3001], INFO, SECURITY, , , , Event: , Status: success, Info: Security mode on the fabric. Probable Cause Indicates that the security mode of the fabric was either enabled or disabled. Recommended Action Verify that the security mode change was planned. If the security mode change was planned, no action is required.
81 SEC-3003 SEC-3003 Message AUDIT, , [SEC-3003], INFO, SECURITY, , , , Event: , Status: success, Info: Created policy, with member(s) . Probable Cause Indicates that a new security policy was created with entries. Note: If you use a wildcard (for example, an asterisk) in creating a policy, the audit report displays the wildcard in the event info field.
SEC-3006 81 SEC-3006 Message AUDIT, , [SEC-3006], INFO, SECURITY, , , , Event: , Status: success, Info: Removed member(s) from policy . Probable Cause Indicates that a user has removed the specific members from the specified security policy. Note: If you use a wildcard (for example, an asterisk) in removing members from a policy, the audit report displays the wildcard in the event info field.
81 SEC-3009 SEC-3009 Message AUDIT, , [SEC-3009], INFO, SECURITY, , , , Event: , Status: success, Info: Security Transaction aborted. Probable Cause Indicates that the pending security transaction was aborted. Recommended Action Verify that the security transaction was intentionally aborted. If the security transaction was intentionally aborted, no action is required.
SEC-3012 81 SEC-3012 Message AUDIT, , [SEC-3012], INFO, SECURITY, , , , Event: , Status: success, Info: Temp Passwd on domain [] for account []. Probable Cause Indicates that a user has reset the password for the specified user accounts. Recommended Action Verify that the password was intentionally reset. If the password was intentionally reset, no action is required.
81 SEC-3015 SEC-3015 Message AUDIT, , [SEC-3015], INFO, SECURITY, , , , Event: , Status: success, Info: Moved RADIUS server to position . Probable Cause Indicates that a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify that the RADIUS server position was intentionally changed.
SEC-3018 81 SEC-3018 Message AUDIT, , [SEC-3018], INFO, SECURITY, , , , Event: , Status: success, Info: Parameter [] changed from [] to []. Probable Cause Indicates that the specified passwdCfg parameter is changed. Recommended Action Verify that the passwdCfg parameter was intentionally changed. If the passwdCfg parameter was intentionally changed, no action is required.
81 SEC-3021 SEC-3021 Message AUDIT, , [SEC-3021], INFO, SECURITY, , , , Event: , Status: failed, Info: Failed login attempt via . Probable Cause Indicates that a failed login attempt occurred. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required.
SEC-3024 81 SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates that the user’s password changed. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
81 SEC-3027 SEC-3027 Message AUDIT, , [SEC-3027], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] []. Probable Cause Indicates that user account properties were changed. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required.
SEC-3030 81 SEC-3030 Message AUDIT, , [SEC-3031], INFO, SECURITY, , , , Event: , Status: success, Info: Probable Cause Indicates the specified secCertUtil operation was performed. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
81 SEC-3033 SEC-3033 Message AUDIT, , [SEC-3033], INFO, SECURITY, , , , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to . Probable Cause Indicates that the specified event has occurred. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
SEC-3037 Recommended Action Severity 81 Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3037 Message AUDIT, , [SEC-3037], INFO, SECURITY, , , , Event: ipfilter, Status: success, Info: ipfilter policy activated.
81 478 SEC-3039 Fabric OS Message Reference 53-1000437-01
Chapter AUDIT SNMP System Messages 82 SNMP-1004 Message AUDIT, , [SNMP-1004], ERROR, CONFIGURATION, , , , Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Action Reset the SNMP configuration to default.
82 480 SNMP-1006 Fabric OS Message Reference 53-1000437-01
Chapter AUDIT SULB System Messages 83 SULB-1001 Message AUDIT, , [SULB-1001], WARNING, FIRMWARE, , , , Firmwaredownload command has started. Probable Cause Indicates that the firmwareDownload command has been entered. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption.
83 SULB-1009 SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates that the firmwareDownload command failed. The additional status code and error code provide debugging information. Table lists firmwareDownload status messages and status codes. Some of them will not show up in this RASLOG message.
SULB-1009 TABLE 9 Status Messages and Status Codes Status Message Status Code "Standby CP booted up." 0x65 "Active and Standby CP failed to gain HA synchronization within 10 minutes." 0x66 "Standby rebooted successfully." 0x67 "Standby failed to reboot." 0x68 “firmwareCommit has started to restore the secondary partition.” 0x69 "Local CP is restoring its secondary partition." 0x6a “Unable to restore the secondary partition.
83 SULB-1009 TABLE 9 484 Status Messages and Status Codes Status Message Status Code “firmwareCommit has started on the local CP. Please use firmwareDownloadStatus and firmwareShow to see the firmware status.” 0x87 “firmwareCommit has started on the remote CP. Please use firmwareDownloadStatus and firmwareShow to see the firmware status.” 0x88 “Please use firmwareDownloadStatus and firmwareShow to see the firmware status.” 0x89 “firmwareDownload command has completed successfully.
SULB-1009 83 Table lists additional firmwareDownload error messages and error codes. They provide more details on why firmwareDownload failed. TABLE 10 Error Messages and Error Codes Error Message Error Code "Image is up-to-date. No need to download the same version of firmware." 0xF “Upgrade is inconsistent. Run the bootEnv (root) command to correct the inconsistency before proceeding.” 0x10 “OSRootPartition is inconsistent.
83 SULB-1009 TABLE 10 Error Messages and Error Codes Error Message Error Code "Failed to install RPM package." 0x2b "Cannot downgrade directly to this version. Downgrade to an intermediate version first and then download the desired version." 0x2c “Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding.” 0x2d "Invalid RPM package. Please reload firmware packages on the file server.
SULB-1009 83 Table 11 lists the firmwareDownload state names and state values. They indicate where in the firmwareDownload process the error occurred.
83 SULB-1010 SULB-1010 Message AUDIT, , [SULB-1010], INFO, FIRMWARE, , , , Firmwarecommit failed (status=0x). Probable Cause Indicates that the firmwareCommit failed. The error code provides debugging information. See Table 11 for more information. Recommended Action If the failure is caused by an inconsistent filesystem, contact your switch service provider.
SULB-1021 83 Probable Cause The BP blade should reboot with the new image, but is still running the old image. This error may indicate that the new image has not been loaded correctly to the specified blade. Recommended Action Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload.
83 SULB-1026 Recommended Action Severity Run the firmwareShow command to verify the firmware versions. If the blade firmware is the same as the active CP firmware, firmwareDownload has completed successfully on the blade. However, if the firmwareCommit operation has been started to repair the secondary partition, at the end of firmwareCommit, the blade firmware version may still be inconsistent with the active CP firmware. In that case, firmwareDownload will automatically be restarted on the blade.
SULB-1033 83 SULB-1033 Message AUDIT, , [SULB-1033], WARNING, FIRMWARE, , , , Switch has completed relocating the internal firmware image. Probable Cause Indicates that the firmwareDownload process has completed normally on the switch. Recommended Action Run the firmwareShow command to verify the firmware versions. Run the switchShow command to make sure the switch is enabled.
83 SULB-1037 Severity 492 Error Fabric OS Message Reference 53-1000437-01
Chapter AUDIT ZONE System Messages 84 ZONE-3001 Message Probable Cause AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \"\". Indicates that a new zone object member or members have been added to the specified zone object set. The zone object type can be "alias", "zone member", "zone" or "zone configuration".
84 ZONE-3003 ZONE-3003 Message Probable Cause AUDIT, , [ZONE-3003], INFO, ZONE, , , , Event: , Status: success, Info: \"\" deleted. Indicates that the specified zone object has been deleted. The zone object type can be “alias”, “zone member”, “zone” or “zone configuration”. The string “...” appears at the end of the zone object member list if the list was truncated in the message.
ZONE-3006 84 ZONE-3006 Message AUDIT, , [ZONE-3006], INFO, ZONE, , , , Event: , Status: success, Info: Current zone configuration disabled. . Probable Cause Indicates that the current zone configuration has been disabled. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
84 ZONE-3009 ZONE-3009 Message AUDIT, , [ZONE-3009], INFO, ZONE, , , , Event: , Status: success, Info: . Probable Cause Indicates that the specified zone transaction has been aborted. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3012 84 ZONE-3012 Message AUDIT, , [ZONE-3012], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" renamed to \"\". Probable Cause Indicates that the specified zone object has been renamed. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
84 ZONE-3015 ZONE-3015 Message AUDIT, , [ZONE-3015], INFO, FABRIC, , , , Event: , Status: success, Info: AD configurations applied. Probable Cause Indicates that the current admin domain (AD) configuration has been saved to flash is being enforced. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
ZONE-3018 84 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates that the specified admin domain (AD) object has been deactivated. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
84 ZONE-3021 ZONE-3021 Message AUDIT, , [ZONE-3021], INFO, FABRIC, , , , Event: , Status: success, Info: AD object \"\" renamed to \"\". Probable Cause Indicates that the specified admin domain (AD) has been renamed. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
ZONE-3024 84 ZONE-3024 Message AUDIT, , [ZONE-3024], INFO, FABRIC, , , , Command: , Status: success, Info: executed. . Probable Cause Indicates that the admin domain ad --transabort operation was successful in the specified AD. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
84 502 ZONE-3025 Fabric OS Message Reference 53-1000437-01