Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2.0 (53-1001187-01, April 2009)

Fabric OS Troubleshooting and Diagnostics Guide 109
53-1001187-01
Equipment status
13
Above minimum—Fan is rotating too quickly.
Unknown—Unknown fan unit installed.
FAULTY—Fan has exceeded hardware tolerance.
Displaying the status of a power supply
1. Connect to the switch and log in as admin.
2. Enter the psShow command:
brcd5300:admin> psshow
Power Supply #1 is OK
V10645,TQ2Z6452916 ,60-0300031-02, B, QCS ,DCJ3001-02P , A,TQ2Z64529
Power Supply #2 is faulty
V10704, TQ2J7040124 ,60-0300031-02, B,CHRKE,SP640-Y01A ,C ,TQ2J7040
The possible status values are:
OK—Power supply functioning correctly.
Absent—Power supply not present.
Unknown—Unknown power supply unit installed.
Predicting failure—Power supply is present but predicting failure.
FAULTY—Power supply is present but faulty (no power cable, power switch turned off, fuse
blown, or other internal error).
Displaying temperature status
1. Connect to the switch and log in as admin.
2. Enter the tempShow command:
switch:admin> tempshow
Sensor State Centigrade Fahrenheit
ID
=================================================
1 Ok 28 82
2 Ok 16 60
3 Ok 18 64
Information displays for each temperature sensor in the switch.
The possible temperature status values are:
OK—Temperature is within acceptable range.
FAIL—Temperature is outside of acceptable range. Damage might occur.