Brocade Access Gateway Administrator's Guide (53-1000605-01, October 2007)

42 Access Gateway Administrator’s Guide
53-1000605-01
Troubleshooting
C
Failover is not working Failover disabled on N_Port. Verify that failover and failback policies are enabled, as follows:
Enter the ag
--failoverShow command with the <port_number>
operand.
Enter the ag
--failbackShow command with the <port_number>
operand.
Command returns “Failback (or Failover) on N_Port <port_number> is
supported.”
If it returns, “Failback (or Failover) on N_Port <port_number> is not
supported.” See “Specifying Preferred Secondary N_Ports” on
page 29.
Access Gateway is mode
not wanted
Access Gateway must be disabled. Disable switch using the switchDisable command.
Enable Access Gateway mode using
the ag
--modeDisable command.
Answer yes when prompted; the switch reboots.
Log in to the switch.
Display the switch settings using the switchShow command. Verify
that the field switchMode displays Fabric OS native mode.
TABLE 6 Troubleshooting (Continued)
Problem Cause Solution