fwAlarmsFilterSet
2
fwAlarmsFilterSet
Enables or disables alarms for Fabric Watch.
Synopsis fwalarmsfilterset [mode]
Description Use this command to configure alarm filtering for Fabric Watch. By turning off the alarms, all
non-environment class alarms are suppressed. By turning on the alarms, all class alarms are
generated.
This command requires a Fabric Watch license.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operand:
mode Specify 1 to enable the alarms, 0 to disable the alarms. If no operand is
specified, the default value is 0 (alarms deactivated). This operand is
optional.
Examples To enable alarms in Fabric Watch:
switch:admin> fwalarmsfilterset
FW: Alarms are already disabled
switch:admin> fwalarmsfilterset 1
FW: Alarms are aleady enabled