Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 273
53-1000436-01
fwShow
2
8 : End-to-End Performance Monitor class
9 : Filter Performance Monitor class
10 : Security class
11 : Resource class
12 : Quit
Select an item => : (1..12) [11] 1
1 : Temperature
2 : Fan
3 : Power Supply
4 : return to previous page
Select an area => : (1..4) [4] 2
=====================================================================
Name Label Last value
-------------------- ------------------------ -------------------
envFan001 Env Fan 1 2576 RPM
envFan002 Env Fan 2 2518 RPM
envFan003 Env Fan 3 2481 RPM
switch:user> fwshow
1 : Show class thresholds
2 : Detail threshold information
3 : Show console message level
4 : Show port persistence time
5 : Quit
Select an item => : (1..3) [3] 2
Enter Threshold Name : [] envFan001
Env Temperature 1:
Monitored for: 1283 (21 mins)
Last checked: 10:50:21 on 02/01/2000
Lower bound: 0 C
Upper bound: 75 C
Buffer Size: 10
Value history: 33 C
Disabled? No
Locked? No
Raw history: 38 C
38 C
38 C
Flags: 0x 40 TRIGGERED
Counter:
Access via: Function call
Address: 0x100155a8
Argument: 0x00000001
Previous: 0x00000026 (38)
Current: 0x00000026 (38)
Events:
Style: Triggered
Event 0 occurred 1 time, last at 16:30:17 on 12/09/2011