Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 297
53-1000436-01
interfaceShow
2
Operands This command has the following operands:
slotnumber For bladed systems only, specify the slot number of the port to display,
followed by a slash (/).
portnumber Specify the port number to display, relative to its slot for bladed systems. Use
switchShow to list valid ports. This operand is optional; if omitted, the
interface information for all ports is displayed.
When no slot number and port number are specified, this command displays the interface
information for all ports on the switch (including non-E_Ports).
Examples To display FSPF interface information:
switch:user> interfaceshow 1/4
idbP = 0x1008b3d0
Interface 4 data structure:
nghbP = 0x1008c668
ifNo = 4
masterPort = 4 (self)
defaultCost = 500
cost = 500
delay = 1
lastScn = 16
lastScnTime = Apr 02 20:01:44.458
upCount = 2
lastUpTime = Apr 02 20:01:44.458
downCount = 1
lastDownTime = Apr 02 20:01:09.050
downReason = 2
iState = UP
Neighbor 4 data structure:
state = NB_ST_FULL
lastTransition = Apr 02 20:01:44.512
nghbCap = 0x0
nghbId = 100
idbNo = 4
remPort = 52
nflags = 0xf
initCount = 1
lastInit = Apr 02 20:01:44.460
firstHlo = Apr 02 20:01:44.473
nbstFull = Apr 02 20:01:44.512
delay = 1
lastScn = 16
&dbRetransList = 0x1008c6a0
&lsrRetransList = 0x1008c6c4
&lsrAckList = 0x1008c6e8
inactTID = 0x1008c768
helloTID = 0x1008c7a0
dbRtxTID = 0x1008c7d8
lsrRtxTID = 0x1008c848
inactTo = 80000
helloTo = 20000
(continued on next page)