Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 489
53-1000436-01
portFlagsShow
2
portFlagsShow
Displays the port status bitmaps for all ports in a switch.
Synopsis portflagsshow
Description Use this command to display the following status for a port:
SNMP Displays whether the port is online or offline.
Physical Displays the port physical status. Valid values are In_Sync and No_Light.
Flags Displays whether there is an SFP inserted in the port, whether the port is active, and
the port type.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the port status for all ports in the switch:
switch:user> portflagsshow
Slot Port SNMP Physical Flags
-----------------------------------------------------
1 0 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 1 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 2 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 3 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 4 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 5 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 6 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 7 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 8 Offline No_Light PRESENT LED
1 9 Offline No_Light PRESENT LED
1 10 Offline No_Light PRESENT LED
1 11 Offline No_Light PRESENT LED
1 12 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 13 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 14 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
1 15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 0 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 1 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 2 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 3 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 4 Offline No_Light PRESENT LED
4 5 Offline No_Light PRESENT LED
4 6 Online In_Sync PRESENT ACTIVE F_PORT L_PORT LOGIN NOELP LED ACCEPT
4 7 Online In_Sync PRESENT ACTIVE F_PORT L_PORT LOGIN NOELP LED ACCEPT
4 8 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 9 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 10 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 11 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 12 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 13 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 14 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
4 15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
See Also portShow, switchShow