Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 535
53-1000436-01
portStatsShow
2
Operands This command has the following operands:
slotnumber For bladed systems only, specifies the slot number of the port to be displayed,
followed by a slash (/).
[ge]portnumber Specifies a port number to be configured, relative to its slot for bladed
systems. Specify the optional ge option to display the GbE port hardware
statistics. Use switchShow to display a list of valid ports.
ge Displays the GbE statistics.
ip Displays all the GbE port statistics related to IP addresses that are on (not
zero). Optionally, use ipaddress to display statistics for the specified IP
address.
fcip Displays the GbE statistics on all FCIP tunnels. Optionally, use tunnelnumber
to display statistics for the specified FCIP tunnel.
Examples To display the basic set of statistics for a port:
switch:admin> portstatsshow 13
stat_wtx 0 4-byte words transmitted
stat_wrx 0 4-byte words received
stat_ftx 0 Frames transmitted
stat_frx 0 Frames received
stat_c2_frx 0 Class 2 frames received
stat_c3_frx 0 Class 3 frames received
stat_lc_rx 0 Link control frames received
stat_mc_rx 0 Multicast frames received
stat_mc_to 0 Multicast timeouts
stat_mc_tx 0 Multicast frames transmitted
tim_rdy_pri 0 Time R_RDY high priority
tim_txcrd_z 0 Time BB credit zero
er_enc_in 0 Encoding errors inside of frames
er_crc 0 Frames with CRC errors
er_trunc 0 Frames shorter than minimum
er_toolong 0 Frames longer than maximum
er_bad_eof 0 Frames with bad end-of-frame
er_enc_out 0 Encoding error outside of frames
er_bad_os 0 Invalid ordered set
er_c3_timeout 0 Class 3 frames discarded due to timeout
er_c3_dest_unreach 0 Class 3 frames discarded due to destination
unreachable
er_other_discard 0 Other discards
er_zone_discard 0 Class 3 frames discarded due to zone
mismatch
er_crc_good_eof 0 Crc error with good eof
er_inv_arb 0 Invalid ARB
open 0 loop_open
transfer 0 loop_transfer
opened 0 FL_Port opened
starve_stop 0 tenancies stopped due to starvation
fl_tenancy 0 number of times FL has the tenancy
nl_tenancy 0 number of times NL has the tenancy
zero_tenancy 0 zero tenancy
To display GbE port statistics for slot 8 and GbE port 1:
switch:admin> portstatsshow ge 8/ge1
ge_stat_tx_frms 0 GE transmitted frames