Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 619
53-1000436-01
slotPowerOff
2
slotPowerOff
Removes power from a slot.
Synopsis slotpoweroff slotnumber
Description Use this command to turn off the power to a blade unit. The slot must have a valid blade unit
present and the blade unit must be of a type that can be powered off.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operand:
slotnumber Specify the slot number of the blade to be powered down. This operand is
required.
Examples To power off blade unit 3:
switch:admin> slotpoweroff 3
Slot 3 is being powered off
See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow