Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

622 Fabric OS Command Reference Manual
53-1000436-01
slotShow
2
INITIALIZING The blade is present, powered on, and initializing hardware components.
ENABLED The blade is on and enabled.
ENABLED (User Ports Disabled)
The blade is on but the external ports are disabled using bladeDisable.
DISABLED The blade is powered on but disabled.
FAULTY The blade is faulty because an error was detected.
UNKNOWN The blade is inserted but its state cannot be determined.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the status of all slots in the system:
switch:user> slotshow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 17 FAULTY
2 SW BLADE 17 DISABLED
3 SW BLADE 17 ENABLED(User Ports Disabled)
4 SW BLADE 17 DIAG RUNNING POST2
5 CP BLADE 16 ENABLED
6 CP BLADE 16 ENABLED
7 AP BLADE 24 LOADING
8 SW BLADE 17 DIAG RUNNING POST1
9 SW BLADE 17 INSERTED, NOT POWERED ON
10 UNKNOWN VACANT
See Also bladeDisable, bladeEnable, chassisShow, slotPowerOff, slotPowerOn