Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

678 Fabric OS Command Reference Manual
53-1000436-01
switchShow
2
Operands The operand is as follows:
-portcount Causes the switchShow command to display the number of ports on the
switch.
-iscsi Causes the switchShow command to display the number of ports on the iSCSI
sessions associated with GE ports in a switch.
Examples To display the port count:
switch:admin> switchshow -portcount
ports= 64
To display GE ports with iSCSI sessions:
switch:admin> switchshow -iscsi
Ports of Slot 1 ge0 ge1 ge2 ge3 ge4 ge5 ge6 ge7
-----------------+---+---+---+---+-----+---+---+---
Sessions 0 0 0 0 0 0 0 0
NOTE
When a port is configured as an N_Port and is online, switchShow displays its type as an N_Port.
Also, switchShow displays WWN of the of the border switch attached to this N_Port as a 24-bit Port
Identifier assigned to this port by the enterprise fabric.
To display switch information:
switch:admin> switchshow
switchName: top_4a3_a10
switchType: 42.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 3
switchId: fffc03
switchWwn: 10:00:00:60:69:e2:09:be
AD Feature: Not Active
Current AD: 0
zoning: ON (bot_cfg)
switchBeacon: OFF
blade4 Beacon: OFF
blade8 Beacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 1
Index Slot Port Address Media Speed State Proto
===================================================
[output truncated]
80 8 0 035000 id N4 Laser_Flt Disabled (Persistent)
81 8 1 035100 -- N4 No_Module Disabled (Persistent)
82 8 2 035200 -- N4 No_Module Disabled (Persistent)
83 8 3 035300 -- N4 No_Module Disabled (Persistent)
84 8 4 035400 -- N4 No_Module Disabled (Persistent)
85 8 5 035500 -- N4 No_Module Disabled (Persistent)
86 8 6 035600 id N4 No_Light Disabled (Persistent)
87 8 7 035700 id N4 No_Sync Disabled (Persistent)
88 8 8 035800 id N1 Online F-Port
10:00:00:00:c9:25:3d:43