Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 727
53-1000436-01
version
2
version
Displays firmware version information.
Synopsis version
Description Use this command to display firmware version information and build dates.
The following is displayed:
Kernel Displays the version of switch kernel operating system
Fabric OS Displays the version of switch Fabric OS
Made on Displays the build date of firmware running in switch
Flash Displays the build date of firmware stored in flash proms
BootProm Displays the version of the firmware stored in the boot PROM
Usually the Made on and Flash dates are the same, because the switch starts running flash
firmware at power-on. However, in the time period between firmwareDownload and the next reboot,
the dates can differ.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the firmware version information in a switch:
switch:admin> version
Kernel: 2.4.19
Fabric OS: v5.2.0v5.2.0_pit_060911_0600
Made on: Mon Sep 11 18:55:09 2006
Flash: Mon Sep 11 19:26:15 2006
BootProm: 4.5.3
See Also firmwareDownload, reboot