Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 53
53-1000436-01
burninErrClear
2
burninErrClear
Clears errors stored in the nonvolatile memory on the slot during burn-in.
Synopsis burninerrclear slotnumber
Description Use this command to clear errors stored in the nonvolatile memory on the slot during burn-in.
It is advisable to run the burninErrClear command prior to running diagSetBurnin and diagSetCycle
.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands The operand is a follows:
slotnumber A nonzero value that specifies the slot number from which to clear burn-in
errors.
Examples To clear burn-in errors from slot 2.
switch:admin> burninerrclear 2
See Also burninErrShow