Brocade Fabric OS Command Reference Manual - Supporting Fabric OS v5.3.0 (53-1000436-01, June 2007)

Fabric OS Command Reference Manual 55
53-1000436-01
burninLevel
2
burninLevel
Sets the diagnostics burn-in level.
Synopsis burninlevel [level | -show]
Description Use this command to select or display the burn-in level. When the burn-in level is set to a value
other than 0, the diagnostic daemon program performs burn-in testing in place of the power-on
self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as
soon as this command is executed so that it does not require a reboot to take effect.
When a burn-in level other than 0 is selected, actual behavior is determined by the configuration of
the diagnostics daemon and the burn-in scripts run.
A useful application of this command is to store errors on the local persistent error storage on
which the error occurs. This happens when the burn-in level is other than 0. This preserves the
errors prior to returning a board for service. For multibladed products, this is the independent
blade, and for fixed-port-count products, this is the chassis-persistent storage. The error logs are
viewed using the burninErrShow command.
Operands The following are optional:
level The burn-in level sets to this value.
-show If specified, or if level is not specified, the current burn-in level setting
displays.
Examples To set the diagnostic burn-in level:
switch:admin> burninlevel -show
Burnin level is 0.
See Also burninErrShow, diagDisablePost, diagEnablePost, diagSetBurnin