Brocade Fabric OS Documentation Addendum - Supporting Fabric OS v5.2.x (53-1000429-01-HP)

Fabric OS Documentation Addendum 1-33
Publication Number: 53-1000429-01-HP
ipaddrshow
1
ipaddrshow
Displays the IP address information for a switch or control processor (CP).
Synopsis ipaddrshow [-cp cp_number] | [-sw sw_number]
Description Use this command to display the IP addresses configured in the system.
The -cp option displays the CP IP address and the -sw option displays the switch IP addresses. For
switches, the command displays the Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address,
and Fibre Channel subnetmask. For CPs, the command displays the Ethernet IP address, Ethernet
subnetmask, host name, and gateway IP address.
Note
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operands:
-cp cp_number For dual-CP systems, this specifies the CP card number to display (0 or 1).
-sw sw_number For dual-domain systems, this specifies the switch number to display (0 or 1).
If no operands are specified, the command displays all the IP addresses configured in the system. For non
chassis-based switches, this command ignores all operands.
Examples To display the IP address for logical switch 0:
switch:admin> ipaddrshow -sw 0
Ethernet IP Address: 192.168.166.147
Ethernet Subnetmask: 255.255.255.0
Fibre Channel IP Address: 0.0.0.0
Fibre Channel Subnetmask: 0.0.0.0