Brocade Fabric OS Documentation Addendum - Supporting Fabric OS v5.2.x (53-1000429-01-HP)

1-38 Fabric OS Documentation Addendum
Publication Number: 53-1000429-01-HP
portCfgShow Note: Enter commands in lowercase only; mixed case is for readability
1
To display the configuration settings for a port:
To display the configuration settings for a port with agmode enabled:
See Also portCfg, portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgNPIVPort,
portCfgSpeed, portCfgTrunkPort
switch:user> portcfgshow 2/16
Area Number: 144
Speed Level: AUTO
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
Mirror Port OFF
SW4016_5311:admin> portcfgshow
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Locked N_Port .. .. .. .. .. .. .. .. .. .. ON ON .. ON ON ON
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
where AN:AutoNegotiate, ..:OFF, ??:INVALID,
SN:Software controlled AutoNegotiation.