Brocade Fabric OS Documentation Addendum - Supporting Fabric OS v5.2.x (53-1000429-01-HP)

Fabric OS Documentation Addendum 2-3
Publication Number: 53-1000429-01-HP
AG-1003
2
AG-1003
Message
Probable
Cause
Indicates that an F_Port could not be failed over to another N_Port because no other N_Ports were
connected to the same fabric as N_Port that went offline.
Recommended
Action
Connect two or more N_Ports to the same fabric and then enable failover on these N_Ports using the
ag --failoverenable command.
Severity WA RNI NG
AG-1004
Message
Probable
Cause
Indicates that the fabric sent an invalid response to FLOGI ELS of the specified N_Port.
Recommended
Action
Verify the fabric switch's configuration.
If the message persists, run supportFtp to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity ERROR
AG-1005
Message
Probable
Cause
Indicates that the F_Port that connects to the host is offline.
Recommended
Action
Verify the configuration of the host connected to the specified F_Port.
Severity WA RNI NG
<timestamp>, [AG-1003], <sequence-number>,, WARNING, <system-name>,
Not able to fail over N_Port <port>. Fail over across different
fabric is not supported.
<timestamp>, [AUTH-1004], <sequence-number>,, ERROR, <system-name>,
Invalid response to fabric login (FLOGI) request from the fabric for
N_Port <port>.
<timestamp>, [AUTH-1005], <sequence-number>,, WARNING, <system-
name>, FDISC response dropped because F_Port <port> is offline.