Brocade Fabric OS Documentation Addendum - Supporting Fabric OS v5.2.x (53-1000429-01-HP)

2-4 Fabric OS Documentation Addendum
Publication Number: 53-1000429-01-HP
AG-1006
2
AG-1006
Message
Probable
Cause
Indicates that the F_Port that connects to the host did not send FLOGI request for
10 times E_D_TOV. F_Port is disabled.
Recommended
Action
Verify the HBA driver configuration of the host connected to the specified F_Port. Access Gateway
supports Fabric mode connectivity only.
Check Gigabit Interface Converter (GBIC) and other connecting cables and re-enable the F_Port using
the portEnable command.
Severity WA RNI NG
AG-1007
Message
Probable
Cause
Indicates the N_Port which is connected to the fabric switch is not online. The N_Port has been
disabled.
Recommended
Action
Check the connectivity between the Access Gateway N_Port and the fabric switch port.
Severity WA RNI NG
AG-1008
Message
Probable
Cause
Indicates that the fabric switch management server did not accept the login (PLOGI) request sent by the
Access Gateway from the specified N_Port.
Recommended
Action
Verify the configuration on the fabric switch that is connected to the Access Gateway.
If the message persists, run supportFtp to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity WA RNI NG
<timestamp>, [AG-1006], <sequence-number>,, WARNING, <system-name>,
FLOGI request was not received from F_Port <port>. Port is being disabled
<timestamp>, [AG-1007], <sequence-number>,, WAR NI NG , <system-
name>, FLOGI response not received for the N_Port <port> connected
to fabric
<timestamp>, [AG-1008], <sequence-number>,, WARNING, <system-name>,
Invalid PLOGI response from the fabric on the N_Port <port>