Brocade Fabric OS Documentation Addendum - Supporting Fabric OS v5.2.x (53-1000429-01-HP)

Fabric OS Documentation Addendum 2-5
Publication Number: 53-1000429-01-HP
AG-1009
2
AG-1009
Message
Probable
Cause
Indicates that the fabric login (FLOGI) request sent to the fabric switch from the Access Gateway
failed.
Recommended
Action
Verify the configuration of the fabric switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WA RNI NG
AG-1010
Message
Probable
Cause
Indicates an internal problem with the Secure Fabric OS.
Recommended
Action
Verify the configuration of the fabric switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WA RNI NG
AG-1011
Message
Probable
Cause
Indicates that the discover F_Port service parameters (FDISC) request sent to the fabric switch from the
Access Gateway failed.
Recommended
Action
Verify the configuration of the fabric switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WA RNI NG
<timestamp>, [AG-1009], <sequence-number>,, WARNING, <system-name>,
FLOGI sent from N-Port <port> failed
<timestamp>, [AG-1010], <sequence-number>,, WARNING, <system-name>,
PLOGI sent from N-Port <port> failed
<timestamp>, [AG-1011], <sequence-number>,, WARNING, <system-name>,
FDISC sent from N-Port <port> failed