Brocade Fabric Watch Administrator's Guide (53-1000243-01, November 2006)

Fabric Watch Administrator’s Guide A-17
Publication Number: 53-1000243-01
Default Threshold Values
A
SFP Class
Table A-11 provides default settings for areas in the SFP class.
N
ote
SFPs connected to GbE ports are not monitored.
Table A-11 SFP Class Threshold Defaults
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
Current Monitors SFP
current
Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Receive Power Monitors receive
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Supply Voltage Monitors SFP
electrical force in
volt(s)
Unit: mV
Time Base: none
Low: 3150
High: 3600
Buffer: 10
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Temperature Monitors SFP
Temperature
Unit: Degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3
Changed: 0
Below: 1
Above: 1
In-Between: 1
Informative
Out_of_range
Out_of_range
Normal
Transmit
Power
Monitors transmit
power in µWatts
Unit: µWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Normal