Brocade Fabric Watch Administrator's Guide (53-1000243-01, November 2006)

A-2 Fabric Watch Administrator’s Guide
Publication Number: 53-1000243-01
Default Threshold Values
A
Environment Class
Table A-1 provides default settings for areas in the Environment class. These defaults are hardware-
dependent. Check the appropriate hardware reference manual for differences in environmental
requirements.
N
ote
For the SilkWorm 200E, there is no fan default threshold because the fans are not monitored by Fabric
Watch. You can use the fanShow command to view the SilkWorm 200E fan status (OK or NOT OK).
However, you cannot use the fwConfigure command to manipulate the threshold or alarm actions
against any fans.
Table A-1 Environment Class Threshold Defaults
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
Fan Monitors switch fan
speed in RPMs
Unit: RPM
Time Base: none
SilkWorm 3850 and
3250
Low: 4500
High: 11000
Buffer: 3
SilkWorm 3900
Low: 2600
High: 10000
Buffer: 3
SilkWorm 4100
Low: 3000
High: 12000
Buffer: 3
SilkWorm 4900
Low: 4100
High: 8500
Buffer: 3
SilkWorm 7500
Low: 5000
High: 16000
Buffer: 3
SilkWorm 24000
Low: 1600
High: 3400
Buffer: 3
SilkWorm 48000
Low: 1600
High: 3400
Buffer: 3
Changed: 0
Above: 3
Below: 3
In-Between: 1
Informative
Out_of_range
Out_of_range
In_range