Brocade Fabric Watch Administrator's Guide (53-1000243-01, November 2006)

Fabric Watch Administrator’s Guide A-5
Publication Number: 53-1000243-01
Default Threshold Values
A
Fabric Class
Table A-2 provides default settings for areas in the Fabric class. These defaults are hardware-dependent.
Check the appropriate Hardware Reference Manual for differences in environmental requirements.
Table A-2 Fabric Class Threshold Defaults
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
Domain ID
Changes
Monitors forcible
DOMAIN ID
changes
Unit: D_ID Change(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
SFP State Changes Monitors the
insertion and
removal of SFPs
Unit: Change(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Loss of E_Port Monitors E_Port
and VE_Port status
Unit: Down(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Fabric Logins Monitors host
device fabric logins
Unit: Login(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative