Brocade Fabric Watch Administrator's Guide (53-1000243-01, November 2006)

A-6 Fabric Watch Administrator’s Guide
Publication Number: 53-1000243-01
Default Threshold Values
A
Performance Monitor Class
Table A-3 provides default settings for areas in the AL_PA Performance Monitor class.
Fabric
Reconfiguration
Monitors
configuration
changes
Unit: Reconfig(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Segmentation
Changes
Monitors
segmentation
changes
Unit: Segmentation(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
SFP State Changes Monitors SFP state
changes
Unit: Change(s)
Time Base:
Low: 0
High: 0
Buffer: 0
Changed: 0
Exceeded: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Informative
Informative
Informative
Zoning Changes Monitors changes
to currently enabled
zoning
configurations
Unit: Zone change(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Table A-3 AL_PA Performance Monitor Class Threshold Defaults
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
AL_PA Invalid
CRCs
Monitors the number
of arbitrated loop
physical address
CRC errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 60
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Table A-2 Fabric Class Threshold Defaults (Continued)
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
N
ote
End-to-end and AL_PA CRC counters are not supported on the Silkworm 200E switch, 4100 switch,