Brocade Fabric Watch Administrator's Guide (53-1000243-01, November 2006)

Fabric Watch Administrator’s Guide A-9
Publication Number: 53-1000243-01
Default Threshold Values
A
Primitive Sequence
Protocol Error
Monitors the
number of
primitive
sequence errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive
Performance
Monitors receive
rate, by
percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: Change(s)
Time Base: minute
Low:0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors
transmission rate,
by percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Table A-6 Port Class Threshold Defaults (Continued)
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State