Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2.0 (53-1001187-01, April 2009)

Fabric OS Troubleshooting and Diagnostics Guide 47
53-1001187-01
Considerations for downgrading firmware
5
Considerations for downgrading firmware
To avoid failure of a firmware downgrade, verify the firmware you are downgrading to supports all
the blades in the chassis and supports all features you are currently using. If not, you will need to
disable or remove those features that are not supported. Also, check for any one of the following
conditions:
If an FC8-32 or FC8-48 port blade, or both, is inserted on a Brocade 48000 director or Brocade
DCX or DCX-4S enterprise-class platform, power off and remove the blade prior to downgrading
the firmware.
If an EX_Port is configured and enabled on any one of the FC8-port blades, reconfigure the
port back to default prior to downgrading the firmware.
If port mirroring is configured and enabled on any one of the FC8-port blades, reconfigure the
port back to default prior to downgrading the firmware.
If Access Gateway ADS policy is enabled, disable ADS policy prior to downgrading the firmware.
If F_Port Trunking is enabled, disable it first prior to downgrading.
Preinstallation messages
The messages in this section are displayed if an exception case is encountered during firmware
download. The following example shows feature-related messages that you may see if you were
downgrading from v6.2.0 to v6.1.0:
The following items need to be addressed before downloading the specified
firmware:
Non-disruptive firmwaredownload is not supported when downgrading to 6.1.
Please use firmwaredownload -s to download the 6.1 firmware.
Downgrade is not allowed because VF is enabled. Please run \"lscfg --config\"
and \"lscfg --delete\" commands to remove the non-default LS first, then run
\"fosconfig --disable vf\" to disable VF before proceeding.
Downgrade is not allowed because AG is enabled. Please run \"ag
--modedisable\" command to disable AG mode before proceeding.
This example shows hardware-related messages for the same downgrade example:
ECP:admin> firmwaredownload
Type of Firmware (FOS, SAS, or any application) [FOS]:
TABLE 9 USB error handling
Scenario under which download fails Error handling Action
An access error occurs during
firmwaredownload because the
removal of the USB device, or USB
device hardware failure, etc.
Firmwaredownload will timeout
and commit will be started to
repair the partitions of the CPUs
that are affected. See previous
table for details.
None.
USB device is not enabled. Firmwaredownload will fail with
an error message
Enable the USB device using the
usbStorage -e command and retry
firmwaredownload.