Brocade Fabric OS v6.4.3f Release Notes v1.0

Fabric OS v6.4.3f Release Notes v1.0 Page 101 of 149
Closed with Code Change in Fabric OS v6.4.1b GA March 2, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
March 2, 2011 in Fabric OS v6.4.1b.
Defect ID: DEFECT000283566
Technical Severity: High
Summary: Continuous SNMPd FFDC observed on switch during SNMP queries
Symptom: SNMPd FFDC will occur if a rare race condition is encountered
Feature: Field Escalation
Function: Management Embedded
Probability: Low
Found in Release: FOS6.1.1
Service Request ID: 421557
Defect ID: DEFECT000324135
Technical Severity: High
Summary: Frames received on shared area port trunks are improperly routed.
Symptom: Frame drop caused traffic issue when there are trunks configured on shared area ports on
a FC8-48 port blade in a DCX. It usually happens after the remote trunk master went offline
and comes back online.
Feature: Field Escalation
Function: FC Layer 2 Routing
Probability: Medium
Found in Release: FOS6.4.0
Service Request ID: 464647
Defect ID: DEFECT000324940
Technical Severity: High
Summary: Connectivity issues when 8G port is operating in FL mode
Symptom: In an 8 Gig Switch fabric, on a looped connection with several devices on the loop, user
may experience connection issues such as hosts not able to see its targets, timeouts on
GNN_FT/GA_NXT name server requests etc.
Workaround: Configure a FL port in such a way that the number of buffers > the number of devices in
loop.
Feature: Field Escalation
Function: Scimitar / Sabre Layer-2
Probability: Medium
Found in Release: FOS6.3.1
Defect ID: DEFECT000324969
Technical Severity: High
Summary: Unequal traffic load distribution when multiple tunnels of equal bandwidth are configured
on the Brocade 7800
Symptom: Data path throughput is not optimal
Feature: 8G Platform Services
Function: Routing
Probability: Medium
Found in Release: FOS7.0.0