Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.1
Fabric OS v6.4.3f Release Notes v1.0 Page 129 of 149
Defect ID: DEFECT000304033
Technical Severity: Medium
Summary: On a Brocade 5470, setting the port to fixed 8GB causes boot over SAN to fail with some
3rd party HBAs.
Symptom: Boot over SAN with 3rd party 8G HBA fails with port speed configured fixed to 8GB.
Feature: 8G ASIC Driver
Function: PORT
Probability: Medium
Found in Release: FOS6.3.1
Where Else Fixed: FOS6.4.1, FOS6.3.2 a
Defect ID: DEFECT000308204
Technical Severity: Medium
Summary: After a panic occurs in a Brocade FR4-18i or 7500, the CP attempts to output error
message FCIP-5051 using an uninitialized section of shared memory in the FR4-18i or
7500, causing an "Oops: kernel access of bad area" panic on the CP.
Symptom: A Brocade FR4-18i or 7500 panic occurs followed by a CP panic, with an "Oops: kernel
access of bad area" message seen in the RASLOG.
Feature: FCIP
Function: FCIP CP
Probability: Low
Found in Release: FOS6.3.2
Where Else Fixed: FOS6.4.1, FOS6.3.2 a
Defect ID: DEFECT000308833
Technical Severity: Medium
Summary: IPv4 and IPv6 shows different Webtools behavior in Fabric Tree. Webtools should not be
able to be launched from Fabric Tree when using IPv6
Symptom: Webtools can be launched from Fabric Tree when using auto configured IPv6 address when
it shouldn't be.
Feature: WebMgmt
Function: IPV6
Probability: High
Found in Release: FOS6.1.2
Service Request ID: 443373
Where Else Fixed: FOS6.4.1
Defect ID: DEFECT000311055
Technical Severity: Medium
Summary: Tape pipelining emulation times out after an extended amount of inactivity on the Brocade
7800
Symptom: After a tape drive has been idle for a few hours and then traffic is restarted, the tape
performance is degraded.
Feature: FCIP
Function: Emulation
Probability: Medium
Found in Release: FOS6.3.2
Service Request ID: 444721
Where Else Fixed: FOS6.4.1