Brocade Fabric OS v6.4.3f Release Notes v1.0

Closed with Code Change in Fabric OS v6.4.3f
Fabric OS v6.4.3f Release Notes v1.0 Page 39 of 149
Defect ID:
DEFECT000487235
Technical Severity:
High
Probability:
High
Product:
FOS
Technology:
Virtualization
Reported In Release:
FOS7.1.1
Technology Area:
Access Gateway
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
Hosts are not able to login to the Access Gateway after the Access Gateway is rebooted.
Condition:
The problem occurs under these conditions:
- No Access Gateway policies are enabled -- i.e. neither Port Group policy nor Auto Policy
- Access Gateway is rebooted
- One or more N-ports do not come online after reboot
Workaround:
Insure all N-ports come online after an Access Gateway reboot.
Recovery:
Either bring all required N-ports online or re-map the currently offline F-ports to the online N-port(s).
Defect ID:
DEFECT000489829
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.1.0
Technology Area:
End-to-end Performance
Monitoring
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
RX /Tx performance values higher than 100% on couple of ports
Condition:
These may be seen only when link goes down and comes back up.
Defect ID:
DEFECT000490548
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Traffic Management
Reported In Release:
FOS7.1.1
Technology Area:
BB Credits
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
Detect CRC error with good EOF on C-port(0) and on C-port(8); This could trigger buffer credit loss
on these ports.
Condition:
It happens with Slot 2 port 0 and port 8 of a DCX4s with FC8-48 port cards installed in slot 2.
Recovery:
Manually tune both the port card port and the core blade ports with different values.
Defect ID:
DEFECT000492704
Technical Severity:
High
Probability:
High
Product:
FOS
Technology:
Traffic Management
Reported In Release:
FOS6.4.3
Technology Area:
FC-FC routing
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
"CRC error with good EOF" errors detected and may cause credit loss.
Condition:
DCX-4S with FC8-64 blades installed in Slot 7 port 155, 76 Slot 2 port 154. Core blade 3/19,3/26,
6/70
Recovery:
Auto Tuning/Manual Tuning
Defect ID:
DEFECT000496941
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Other
Reported In Release:
FOS6.4.3
Technology Area:
Other
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
If a16G SFP is accidentally plugged into a 8G blade, instead of getting a Mod_Inv error, it allows
devices to log in, but throws a tremendous amount of enc out errors.
Condition:
16G SFP is mistakenly plugged into 8G blade
Workaround:
Use an 8G SFP