Brocade Fabric OS v6.4.3f Release Notes v1.0

Closed with Code Change in Fabric OS v6.4.3e
Fabric OS v6.4.3f Release Notes v1.0 Page 42 of 149
Defect ID:
DEFECT000429815
Technical Severity:
High
Summary:
BR5480 exhibits snmpd crash and switch reboot when being managed by BNA.
Symptom:
BR5480 switches running in AG mode and managed by BNA exhibit snmpd crash and switch reboot.
Workaround:
Avoid managing an AG switch with BNA or have all ports connected to either N_Port or F_port or
have AG in auto policy disabled state.
Probability:
High
Feature:
FOS Software
Function:
Management Services
Reported In Release:
FOS6.4.2
Service Request ID:
1102791
Defect ID:
DEFECT000430349
Technical Severity:
High
Summary:
Busy BES blade processor may cause LUN discovery to fail.
Symptom:
Host access to LUNs is lost after initiator WWNs are added to the crypto target container (CTC)
Probability:
Medium
Feature:
FOS Software
Function:
Encryption
Reported In Release:
FOS6.4.2
Service Request ID:
1106719
Defect ID:
DEFECT000434819
Technical Severity:
Medium
Summary:
Polling container stats every 30 seconds caused free memory decrease on blade processor.
Symptom:
Continuous decrease in free memory is observed on blade processor when polling container stat every
30 seconds.
Workaround:
Reboot FS8-18 blade or BES switch
Probability:
Medium
Feature:
Data Security
Function:
Disk Encryption
Reported In Release:
FOS7.0.2
Service Request ID:
1102253
Defect ID:
DEFECT000436921
Technical Severity:
High
Summary:
Console print hung and caused other process to unable to complete
Symptom:
In general customer observes switch panic, unable to access switch.
Workaround:
Check console port and make sure the settings are correct
Probability:
Low
Feature:
FOS
Function:
KERNEL
Reported In Release:
FOS6.3.1_dcb
Service Request ID:
1112726
Defect ID:
DEFECT000440989
Technical Severity:
High
Summary:
BNA experiences out of memory error when obtaining or polling for encrypted LUN level info from
two encryption groups that each have 4,000 defined LUNs
Symptom:
BNA restarts after hitting an out of memory error.
Workaround:
Reboot FS8-18 blade or BES switch
Probability:
Low
Feature:
CEE-MANAGEABILITY
Function:
CAL INTERFACE
Reported In Release:
FOS7.1.0
Service Request ID:
1102253
Defect ID:
DEFECT000442080
Technical Severity:
Medium
Summary:
Making auto-tuned value persistent across reboot
Symptom:
Values from serds auto/manual tuning session are lost after poweroff/on blade or cold reboot of
switch.
Probability:
Low
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Reported In Release:
FOS7.0.2