Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.3b
Fabric OS v6.4.3f Release Notes v1.0 Page 51 of 149
Defect ID:
DEFECT000394917
Technical Severity:
Medium
Summary:
Slow CLI response time running FOS v7.x
Symptom:
User may notice the slowness when run a script with many commands; individual command
response time is still within second.
Probability:
Medium
Feature:
FOS Software
Function:
OS: Linux
Reported In Release:
FOS7.0.0
Service Request ID:
721373
Defect ID:
DEFECT000397402
Technical Severity:
Medium
Summary:
Soft parity errors causing disruption on BES/FS8-18
Symptom:
If a parity error occurs in the encryption path, frames may be transmitted to the destination
carrying an incorrect payload and without being marked with an error. If a parity error occurs in
the decryption path, the frame data might not be decrypted successfully.
Probability:
Low
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS6.4.2
Service Request ID:
722589
Defect ID:
DEFECT000399130
Technical Severity:
Medium
Summary:
Switch ports report CRC with Good EOF Errors.
Symptom:
Large number of CRC with good EOF errors on DCX system when an FC8-64 is installed in slot
1,3,9
Probability:
Low
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Reported In Release:
FOS6.4.2
Service Request ID:
721423
Defect ID:
DEFECT000399142
Technical Severity:
High
Summary:
PortPerfShow showing bandwidth utilization being reported as 0
Symptom:
No throughput visible with portperfshow.
Workaround:
HA failover
Probability:
Low
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS6.4.1
Service Request ID:
724189,733703
Defect ID:
DEFECT000399885
Technical Severity:
Medium
Summary:
weblinker file descriptor on CEE platform leaks when monitored by BNA
Symptom:
Customer will experience asserts and weblinker terminations & restarts. This is non disruptive to
customer traffic.
Probability:
High
Feature:
FOS Software
Function:
FCoE
Reported In Release:
FOS7.0.1
Service Request ID:
719205