Defect ID: DEFECT000366776
Technical Severity: Medium
Summary: Fabric Watch may not monitor every SNMP event
Symptom: With High=0 and Low=0, Fabric watch does not monitor every SNMP event.
Feature: Field Escalation
Function: SNMP
Probability: Low
Found in Release: FOS6.3.0
Service Request ID: 664803
Defect ID: DEFECT000366834
Technical Severity: Medium
Summary: Cleanup of crypto stat files fails in error scenarios like rsync failures due to low memory
Symptom: After rsync failure between BP and CP, cyrpto stat files cannot be cleaned up.
Feature: Data Security
Function: Tape Encryption
Probability: Low
Found in Release: FOS7.0.1
Service Request ID: 662425
Defect ID: DEFECT000367446
Technical Severity: Medium
Summary: diagshow displays incorrect speed value for ports on FCOE10-24 blades
Symptom: diagshow displays the backend 4G ports. customer is expecting to see the front end 10G
ports instead
Feature: Diagnostics
Function: Other
Probability: High
Found in Release: FOS6.4.1
Service Request ID: 668999
Defect ID: DEFECT000367452
Technical Severity: Medium
Summary: Using "switchcfgpersistentdisable/enable" can result is subsequent issues with zoning
distribution.
Symptom: Zone DB distribution fails to reach all domains in the fabric.
Feature: Field Escalation
Function: Management Embedded
Probability: Low
Found in Release: FOS6.4.1
Service Request ID: 665233
Defect ID: DEFECT000367920
Technical Severity: Medium
Summary: Port Auto Disable is not triggered on master port in trunk
Symptom: Port Auto Disable (PAD) is not triggered on Master port in Trunk. PAD does trigger on slave
port in trunk.
Feature: FABRIC WATCH
Function: PORT FENCING
Probability: Medium
Found in Release: FOS6.4.2