Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.2b
Fabric OS v6.4.3f Release Notes v1.0 Page 77 of 149
Defect ID: DEFECT000356778
Technical Severity: Medium
Summary: Kernel panic following insertion/removal of SFP on B8000
Symptom: Kernel panic following rapidly insertion/removal of SFP in 10Gbit port on B8000.
Workaround: Please avoid reseating the SFPs in a quick succession.
Feature: Field Escalation
Function: Panic / OOM
Probability: Low
Found in Release: FOS6.4.2
Service Request ID: 634985
Defect ID: DEFECT000356933
Technical Severity: Medium
Summary: configdownload fails with specific timezones
Symptom: config download fails with the following error message:
configDownload: Invalid Time Zone tz = (Asia/Tokyo)
Process function of configdownload failed for filter ts, lrc = -1
Feature: Field Escalation
Function: OS: Configuration
Probability: Low
Found in Release: FOS7.0.0
Service Request ID: 635015
Where Else Fixed: FOS7.0.0 b PATCH
Defect ID: DEFECT000358533
Technical Severity: Medium
Summary: Cold recovery observed when devices that are not LSAN zoned but sending ELS frames.
Symptom: This is observed under rare conditions, in FCR fabrics. Devices that are not LSAN zoned
somehow know the PROXY ID of the other device. ELS frames sent between the devices
that are not LSAN zoned are not properly freed.
Workaround: Use LSAN zone or make sure devices not statically remember old proxy IDs
Feature: Field Escalation
Function: Panic / OOM
Probability: High
Found in Release: FOS6.4.2
Service Request ID: 638173
Defect ID: DEFECT000358765
Technical Severity: Medium
Summary: Switchshow displayed the GE port of BR7500/FR4-18i as "FCIP Copper"
Symptom: BR7500 and FR4-18i has optical SFP in GbE port; not copper, but switchshow displayed it
as "Copper" and no other functional impact.
Workaround: Run the portcfgdefault CLI on the GE ports
Feature: Legacy FCIP (7500/FR4-18i)
Function: FCIP CLI
Probability: High
Found in Release: FOS6.4.2
Service Request ID: 629097